Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AARON ARCHITECTURAL IRON, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of AARON ARCHITECTURAL IRON, LLC in 107 WEST BARRON AVENUE, EVERMAN, TX 76140 (NAICS 332323). OSHA activity number 348629361.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Aaron Architectural Iron, LLC — free Get an email when a new federal OSHA severe-injury report for Aaron Architectural Iron, LLC is published. One employer, no account, unsubscribe in one click.
Site address
107 WEST BARRON AVENUE
City
EVERMAN
State
TX
ZIP
76140
Mailing
107 WEST BARRON AVENUE, EVERMAN, TX 76140
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332323
Employees
59
Ownership type
A

5 citations on file for this inspection.

1910.1200 G08

Serious Gravity 1 1 instance 55 exposed
Issued
May 7, 2026
Abate by
May 29, 2026
Penalty
Initial $3,972 · Current $2,383 Reduced
29 CFR  1910.1200(g)(8):   The employer did not ensure that Safety Data Sheets were readily accessible during each work shift to employees when they were in their work area(s)  On or about December 8, 2025, and at times prior thereto, Safety Data Sheets were not readily accessible to employees in the painting and welding area(s).
Recent events (2)
  • — I (S) $2383.2
  • — Z (S) $3972

1910.1200 H01

Serious Gravity 1 1 instance 55 exposed
Issued
May 7, 2026
Abate by
May 29, 2026
Penalty
Initial $3,972 · Current $2,383 Reduced

Hazardous substances 1340D150

29 CFR  1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  On or about December 8, 2025, and at times prior thereto, employees were not provided with effective information and training on hazardous chemicals used in the painting and welding area(s).
Recent events (2)
  • — I (S) $2383.2
  • — Z (S) $3972

1910.132 D02

Other-than-serious 1 instance 59 exposed
Issued
May 7, 2026
Abate by
May 29, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.132(d)(2):The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2):  On or about December 8, 2025, the employer did not certify, in writing, that the workplace hazard assessment had been performed to address potential hazards employee(s) would potentially face.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 E01

Other-than-serious 1 instance 55 exposed
Issued
May 7, 2026
Penalty
Initial $632 · Current $379 Reduced
29 CFR  1910.157(e)(1):The employer shall be responsible for the inspection, maintenance and testing of all portable fire extinguishers in the workplace.  On or about December 8, 2025, the employer did not inspect and provide maintenance and testing of all portable fire extinguishers throughout in the shop.
Recent events (2)
  • — I (O) $379.2
  • — Z (O) $632

1910.178 L06

Other-than-serious Gravity 5 1 instance 4 exposed
Issued
May 7, 2026
Abate by
May 29, 2026
Penalty
Initial $6,621 · Current $0 Reduced
29 CFR  1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  On or about December 8, 2025, and at times prior thereto, the employer did not certify training for employee(s) operating the Toyota and John Deer powered industrial truck(s).
Recent events (2)
  • — I (O) $0
  • — Z (S) $6621

View Aaron Architectural Iron, LLC's full OSHA safety record →