Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: THE BAILLIE GROUP

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of THE BAILLIE GROUP in 23830 4TH STREET, TREMPEALEAU, WI 54661 (NAICS 321113). OSHA activity number 348629817.

Watch THE Baillie Group — free Get an email when a new federal OSHA severe-injury report for THE Baillie Group is published. One employer, no account, unsubscribe in one click.
Establishment
THE BAILLIE GROUP
Site address
23830 4TH STREET
City
TREMPEALEAU
State
WI
ZIP
54661
Mailing
23830 4TH ST, TREMPEALEAU, WI 54661
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
321113
Employees
35
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $4823.00 · Current $3376.00 Reduced
29 CFR  1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):   (a) Sawmill, head saw; On or about December 3, 2025, the energy control procedure utilized for isolating the carriage during maintenance tasks was not specific and did not identify steps for isolation and control of pneumatic energy sources.
Recent events (2)
  • — I (S) $3376.1
  • — Z (S) $4823

1910.147 C06 I

Serious Gravity 1 1 instance 16 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(c)(6)(i):The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:   (a) Sawmill; On or about December 3, 2025, the employer did not conduct periodic inspections of the energy control procedures to ensure they were accurate and the requirements of the standard were being followed for operations including, but not limited to, the head saw, edger, resaw, and the debarker.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06 I B

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(c)(6)(i)(B):The periodic inspection of the energy control procedure was not conducted to correct any deviations or inadequacies identified:   (a) Sawmill, head saw; On or about December 3, 2025, the energy control procedure utilized for sharpening or changing saw blades did not include carriage feed pump disconnect change of location.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $6431.00 · Current $4502.00 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   (a) Crosby Edger; On November 25, 2025, the infeed conveyors had metal board stops that created pinch points. An employee's finger was pinched between the metal board stop and a fixed guard which resulted in an injured finger that required surgery.
Recent events (2)
  • — I (S) $4501.7
  • — Z (S) $6431

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348629817.