COLORADO SPRINGS, CO —
OSHA Inspection: EL LEON SIDING LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EL LEON SIDING LLC in 10760 LEWANEE POINT, COLORADO SPRINGS, CO 80908 (NAICS 238170). OSHA activity number 348632183.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- EL LEON SIDING LLC
- Site address
- 10760 LEWANEE POINT
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80908
- Mailing
- 800 S SANTA FE AVE LOT A16, FOUNTAIN, CO 80817
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 2
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.451 F07
- Issued
- Dec 30, 2025
- Abate by
- Feb 5, 2026
- Penalty
- Initial $3,972 · Current $2,400 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. a) On or about August 14, 2025, and at times prior, two employees installing siding were exposed to fall hazards greater than 10 ft while working on a pump jack scaffold. The employer failed to ensure a competent person constructed the scaffold. The scaffold had two open sides on the ends of the platform and no bracing at the bottom of the scaffold. The scaffold was utilized at least 20 feet in the air. Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $2400
- — Z (S) $3972
1926.451 G04 I
- Issued
- Dec 30, 2025
- Abate by
- Feb 5, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(4)(i):Guardrail systems were not installed along all open sides and ends of platforms. a.) On or about August 14, 2025, and at times prior, two employees installing siding were exposed to fall hazards greater than 10 feet while working on a pump jack scaffold. The employer failed to ensure employees were protected from falls by installing guardrail systems along all open sides, including the ends of the platform. The two sides were left open. Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 J02
- Issued
- Dec 30, 2025
- Abate by
- Feb 5, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. a) On or about August 14, 2025, employees were exposed to fall hazards in that, pump jack poles were not secured at the bases to prevent movement. Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Dec 30, 2025
- Abate by
- Feb 5, 2026
- Penalty
- Initial $2,838 · Current $1,008 Reduced
General-duty citation text
29 CFR 1926.501(b)(13):Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a.) On or about August 14, 2025, one employee was framing and was exposed to fall hazards greater than 6 feet while balancing on a single beam of the building's frame. The employer failed to ensure employees were protected from falls by having employees utilize a fall protection system or guardrails. Abatement certification and documentation are required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (2)
- — I (S) $1008
- — Z (S) $2838
More inspections in this industry (NAICS 238170)
More inspections in CO
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348632183.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.