Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GAITHER TOOL CO.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of GAITHER TOOL CO. in 2255 WEST MORTON AVENUE, JACKSONVILLE, IL 62650 (NAICS 333514). OSHA activity number 348632274.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Gaither Tool CO. — free Get an email when a new federal OSHA severe-injury report for Gaither Tool CO. is published. One employer, no account, unsubscribe in one click.
Establishment
GAITHER TOOL CO.
Site address
2255 WEST MORTON AVENUE
City
JACKSONVILLE
State
IL
ZIP
62650
Mailing
2255 WEST MORTON AVENUE, JACKSONVILLE, IL 62650
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333514
Employees
7
Ownership type
A

5 citations on file for this inspection.

1910.178 L01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 26, 2026
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l):  On or about December 9, 2025, employees were exposed to physical hazards through the operation of a powered industrial truck, and the employer did not provide the required forklift operator training. This training would include:  a. Formal instruction (lecture, discussion, interactive computer learning, video tape, written material), b. Practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and c. Evaluation of the operator's performance in the workplace.
Recent events (1)
  • — Z (S) $0

1910.178 L01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 26, 2026
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(ii): Prior to permitting an employee to operate a powered industrial truck (except for training purposes), the employer did not ensure that each operator had successfully completed the training required by paragraph (l):  On or about December 9, 2025, prior to allowing employees to operate the powered industrial truck, the employer did not ensure that each operator had completed formal instruction training, practical training, and an evaluation.
Recent events (1)
  • — Z (S) $0

1910.178 L03

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 26, 2026
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(3): Powered industrial truck operators did not receive initial training regarding operating instructions, warnings, and precautions for the types of truck the operator was authorized to operate:  On or about December 9, 2025, employees operating the Yale fork truck have not received any initial training and certification prior to use and the employer does not have a formal or written powered industrial vehicle program.
Recent events (1)
  • — Z (S) $0

1910.212 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 26, 2026
Abate by
Apr 24, 2026
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding were not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  On or about December 9, 2025, employee operating the Winntec Y461555 50 ton heavy duty Jack Press was exposed to potential flying debris, shrapnel, or part ejections while performing pressure testing on the air bottle neck jacks and the employer did not provide one or more methods of machine guarding.
Recent events (1)
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 26, 2026
Abate by
Apr 6, 2026
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  On or about December 9, 2025, employees working near the Winntec Jack Press were exposed to electrical and fire hazards because a box fan was plugged into an extension cord and the extension cord was plugged into a relocatable power strip.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348632274.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.