OSHA Inspection: ABBVIE INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ABBVIE INC. in 1401 SHERIDAN ROAD, NORTH CHICAGO, IL 60064 (NAICS 325412). OSHA activity number 348632340.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Abbvie INC. — free Get an email when a new federal OSHA severe-injury report for Abbvie INC. is published. One employer, no account, unsubscribe in one click.
Establishment
ABBVIE INC.
Site address
1401 SHERIDAN ROAD
City
NORTH CHICAGO
State
IL
ZIP
60064
Mailing
1401 SHERIDAN ROAD, NORTH CHICAGO, IL 60064
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
325412
Employees
1800
Ownership type
A

3 citations on file for this inspection.

1910.147 C07 I A

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
May 15, 2026
Abate by
Jun 11, 2026
Penalty
Initial $13,240 · Current $13,240
1910.147(c)(7)(i)(A)  Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolattion        a)On or about December 3, 2025, the employer did not fully document in the authorized employee training the means and methods for visually confirming that the exhaust fan and the connected belt and pulley that had been locked out at the electrical energy source had ceased all motion prior to removal of the guard that was located in front of the exhaust fan to prevent employee access to the exhaust fan and the connected belt and pulley.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (O) $13240
  • — Z (S) $13240

1910.147 D

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
May 15, 2026
Abate by
Jun 11, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  a) Exhaust fan - On or about December 3, 2025, employees were exposed to machine hazards associated with moving parts while performing maintenance and servicing tasks on exhaust fan. The employer did not implement energy control application steps as the exhaust fan was not properly deenergized to perform maintenance on exhaust fan [per the 1910.147(d)(5) requirements]. As a result, the remaining applicable energy control elements, involving dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C05 I

Deleted Serious Gravity 10 1 instance 1 exposed
Issued
May 15, 2026
Abate by
Jun 11, 2026
Penalty
Initial $13,240 · Current $0 Reduced
29 CFR  1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources:   a) Machine Room - On or about December 3, 2025, the employer did not provide effective means or equipment to isolate, secure or block hazardous energy sources, such as block/pin/chain for the fan blade of the exhaust fan. Employees were exposed to kinetic energy from the fan blades and fan belt.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement or other written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $13240

View Abbvie INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348632340.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.