MEADVILLE, PA —
OSHA Inspection: CHANNELLOCK, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CHANNELLOCK, INC. in 1306 SOUTH MAIN STREET, MEADVILLE, PA 16335 (NAICS 332216). OSHA activity number 348634379.
Where did this inspection happen?
- Establishment
- CHANNELLOCK, INC.
- Site address
- 1306 SOUTH MAIN STREET
- City
- MEADVILLE
- State
- PA
- ZIP
- 16335
- Mailing
- 1306 SOUTH MAIN STREET, MEADVILLE, PA 16335
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332216
- Employees
- 248
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.218 A02
- Issued
- Abate by
- Penalty
- Initial $16550.00 · Current $14000.00 Reduced
General-duty citation text
29 CFR 1910.218(a)(2): Inspection and maintenance. It shall be the responsibility of the employer to maintain all forge shop equipment in a condition which will insure continued safe operation. a.) Channellock, Inc. 1306 South Main Street Meadville, PA 16335, Forge Shop, on or about 10/23/2025, and times prior thereto: Employee was operating the Ceco 1500-2 Re-Strike Hammer in the Forge Shop Area when the safety pull-back device failed. The rope on the Possons Pull-back safety device broke resulting in an employees hand getting crushed by the top die. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation. This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement. IN ADDITION, abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic, or video evidence or abatement or other written records.
Recent events (2)
- — I (S) $14000
- — Z (S) $16550
1910.218 A02 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.218(a)(2)(ii): There was no scheduling and recording of inspections of guards and point of operation protection devices at frequent and regular intervals for forging machine(s): a.) Channellock, Inc. 1306 South Main Street Meadville, PA 16335, Forge Shop, on or about 10/23/2025, and times prior thereto: Frequent inspections not conducted on key safety components including, but not limited to, the area where the rope passes through the eyelet at the Ceco 1500-2 Re-Strike Hammer in the Forge Shop Area. ABATEMENT CERTIFICATION AND DOCUMENTATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation. This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement. IN ADDITION, abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photographic, or video evidence or abatement or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV
- Issued
- Penalty
- Initial $6029.00 · Current $1000.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv):Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv). a.) Channellock, Inc. 1306 South Main Street Meadville, PA 16335, Forge Shop, on or about 12/10/2025, and times prior thereto: A Flexible cord was used as a means of fixed wiring for the 110V computer station located at the Ceco 1500-2 Re-Strike Hammer. NO ABATEMENT CERTIFICATION OR DOCUMENATION REQUIRED
Recent events (2)
- — I (S) $1000
- — Z (S) $6029
1910.303 B07 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(7)(i):Unused opening in electrical cabinets were not effectively closed provide substantially equivalent protection to the equipment: a.) Channellock, Inc. 1306 South Main Street Meadville, PA 16335, Forge Shop, on or about 12/10/2025, and times prior thereto: An electrical knockout was missing on the 240V disconnect at Ceco 1500-2 Re-Strike Hammer. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A02
- Issued
- Abate by
- Penalty
- Initial $12059.00 · Current $5000.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(2): Machine guard(s) on machine(s) were so installed that they offered accident hazards in themselves: a.) Channellock, Inc. 1306 South Main Street Meadville, PA 16335, Forge Shop, on or about 12/10/2025, and times prior thereto: Employees wear gloves under the Possons Pull-back safety device wrist straps at the Ceco 1500-2 Re-Strike Hammer in the Forge Shop Area. b.) Channellock, Inc. 1306 South Main Street Meadville, PA 16335, Forge Shop, on or about 12/10/2025, and times prior thereto: Employees wear gloves under the Possons Pull-back safety device wrist straps at the Ceco 1500-1 Re-Strike Hammer in the Forge Shop Area.
Recent events (2)
- — I (S) $5000
- — Z (S) $12059
1910.1200 F06 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(f)(6)(ii): Except as provided in 29 CFR 1910.1200(f)(7) and 29 CFR 1910.1200(f)(8), the employer did not ensure that each container of hazardous chemicals in the workplace was labeled, tagged or marked with the product identifier and words, pictures, symbols, or combination thereof, which provide at least general information regarding the hazards of the chemicals and which, in conjunction with the other information immediately available to employees under the hazard communication program, would provide employees with the specific information regarding the physical and health hazards of the hazardous chemical a.) Channellock, Inc. 1306 South Main Street Meadville, PA 16335, Forge Shop, on or about 12/10/2025, and times prior thereto: A secondary container of Shell Air Tool A100 oil located at the Ceco 1500-2 Re-Strike Hammer in the Forge Shop was not labeled with a product identifier nor with the correct hazard label associated with the chemical(s) contained therein. NO ABATEMENT CERTIFICATION OR DOCUMENATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.145 E02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.145(e)(2):The wording of signs was not easily read and concise. a.) Channellock, Inc. 1306 South Main Street Meadville, PA 16335, Forge Shop, on or about 12/10/2025, and times prior thereto: The safety labels on the Ceco 1500-2 Re-Strike Hammer were not legible. The safety labels on the Possons pullback device were illegible. b.) Channellock, Inc. 1306 South Main Street Meadville, PA 16335, Forge Shop, on or about 12/10/2025, and times prior thereto: The safety labels on the Ceco 1500-1 Re-Strike Hammer were not legible. A yellow caution sign on the machine and the safety labels on the Possons pullback device were illegible. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at CHANNELLOCK, INC.
MEADVILLE, PA—2026-01-29
CHANNELLOCK, INC.
MEADVILLE, PA—2026-01-08
CHANNELLOCK, INC.
MEADVILLE, PA—2021-11-22 00:00:00
CHANNELLOCK, INC.
MEADVILLE, PA—2019-12-03 00:00:00
CHANNELLOCK, INC.
MEADVILLE, PA—1985-02-07
CHANNELLOCK INC
View CHANNELLOCK, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332216)
LAPEER, MI—2026-05-13
ALDEN MANUFACTURING
MINNEAPOLIS, MN—2026-04-16
111071 - WARNER MANUFACTURING COMPANY
NEW BRITAIN, CT—2026-04-14
STANLEY BLACK - DECKER, INC.
ELK GROVE VILLAGE, IL—2026-03-13
KLEIN TOOLS, INC.
ALLENTOWN, PA—2026-03-12
FRAMEWORK TECHNOLOGIES, INC.
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348634379.