MEADVILLE, PA —
OSHA Inspection: CHANNELLOCK, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CHANNELLOCK, INC. in 1306 SOUTH MAIN STREET, MEADVILLE, PA 16335 (NAICS 332216). OSHA activity number 348675463.
Where did this inspection happen?
- Establishment
- CHANNELLOCK, INC.
- Site address
- 1306 SOUTH MAIN STREET
- City
- MEADVILLE
- State
- PA
- ZIP
- 16335
- Mailing
- 1306 SOUTH MAIN STREET, MEADVILLE, PA 16335
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332216
- Employees
- 248
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.28 B01 I
- Issued
- Abate by
- Penalty
- Initial $10050.00 · Current $7035.00 Reduced
General-duty citation text
29 CFR 1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i): a.) Channellock, Inc. 1306 South Main Street Meadville, PA 16335, on or about 01/08/2026 and times prior thereto: Employees were exposed to fall hazards associated with an unguarded 5 foot open Gas Mac Furnace pit in the Heat Treat Department . Guardrail was removed to work on the conveyor of the Gas Mac Furnace exposing employees to 5 foot fall hazards. ABATEMENT CERTIFICATION REQUIRED: Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of the abatement.
Recent events (2)
- — I (S) $7035
- — Z (S) $10050
1926.451 F03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a.) Channellock, Inc. 1306 South Main Street Meadville, PA 16335, Forge Shop, on or about 01/08/2026, and times prior thereto: Employees are exposed to hazards associated with the Terek TS20 scissor lift in the Compressor Room Area. Hazards include, but are not limited to, exposed electrical wires at the control box, hole on the side of control box, bent/damaged railing, and electrical tape on the electrical plug at the bottom of the lift. An inspection completed by a qualified person would identify the hazards with the lifts and the need to take the lifts out of service until repairs are made. b.) Channellock, Inc. 1306 South Main Street Meadville, PA 16335, Forge Shop, on or about 01/08/2026, and times prior thereto: Employees are exposed to hazards associated with the JLG 2032E2 scissor lift in the Compressor Room Area. Hazards include, but are not limited to, multiple safety and directional labels on the JLG 2032E2 scissor lift were not legible to the operators of the lift. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.242 A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition: a.) Channellock, Inc. 1306 South Main Street Meadville, PA 16335, Forge Shop, on or about 01/08/2026 and times prior thereto: Employees are exposed to hazards associated with a bent prybar in the Heat Treat Department area while performing maintenance tasks. ABATEMENT CERTIFICATION REQUIRED: Abatement certification is required within 10 days after the abatement date noted on the citation (see below). This certification shall include a statement that abatement is complete, the date abatement was completed, method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at CHANNELLOCK, INC.
MEADVILLE, PA—2026-01-29
CHANNELLOCK, INC.
MEADVILLE, PA—2025-12-10
CHANNELLOCK, INC.
MEADVILLE, PA—2021-11-22 00:00:00
CHANNELLOCK, INC.
MEADVILLE, PA—2019-12-03 00:00:00
CHANNELLOCK, INC.
MEADVILLE, PA—1985-02-07
CHANNELLOCK INC
View CHANNELLOCK, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 332216)
LAPEER, MI—2026-05-13
ALDEN MANUFACTURING
MINNEAPOLIS, MN—2026-04-16
111071 - WARNER MANUFACTURING COMPANY
NEW BRITAIN, CT—2026-04-14
STANLEY BLACK - DECKER, INC.
ELK GROVE VILLAGE, IL—2026-03-13
KLEIN TOOLS, INC.
ALLENTOWN, PA—2026-03-12
FRAMEWORK TECHNOLOGIES, INC.
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348675463.