Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: PRO-TROOP LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of PRO-TROOP LLC in 8751 W. 50TH STREET, MC COOK, IL 60525 (NAICS 561720). OSHA activity number 348634791.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Pro-Troop LLC — free Get an email when a new federal OSHA severe-injury report for Pro-Troop LLC is published. One employer, no account, unsubscribe in one click.
Establishment
PRO-TROOP LLC
Site address
8751 W. 50TH STREET
City
MC COOK
State
IL
ZIP
60525
Mailing
1506 N. THROOP STREET, CHICAGO, IL 60642
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561720
Employees
209
Ownership type
A

2 citations on file for this inspection.

1910.147 C06 I

Serious Gravity 10 1 instance 2 exposed
Issued
Mar 19, 2026
Abate by
Apr 14, 2026
Penalty
Initial $11,916 · Current $10,000 Reduced
29 CFR  1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:  a. Oven Room - On or about January 8, 2026,  and days prior to, employees were required to perform service and maintenance on the MPO Ovens.  However, the employer did not ensure periodic inspections of the energy control procedures were performed at least annually as required by the standard.
Recent events (2)
  • — I (S) $10000
  • — Z (S) $11916

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 19, 2026
Abate by
Apr 14, 2026
Penalty
Initial $11,916 · Current $0 Reduced
29 CFR  1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):  a. Oven Room, Oven #5 - On or about December 6, 2025, an employee was exposed to machine hazards associated with moving and rotating parts while cleaning MPO Oven #5, resulting in a right index finger amputation.   The employer failed to implement energy control application steps as the machine was not shut down or turned off to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)((i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $11916

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348634791.