PORT HUENEME, CA —
OSHA Inspection: J DAVIS CONSTRUCTION MANAGEMENT INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of J DAVIS CONSTRUCTION MANAGEMENT INC in NAVAL BASE VENTURA COUNTY, BLDG. 1184 CONTRACT # N62473-19-D-2620, REPLACE ROOF PH1184, PORT HUENEME, CA 93043 (NAICS 238160). OSHA activity number 348635301.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- J DAVIS CONSTRUCTION MANAGEMENT INC
- Site address
- NAVAL BASE VENTURA COUNTY, BLDG. 1184 CONTRACT # N62473-19-D-2620, REPLACE ROOF PH1184
- City
- PORT HUENEME
- State
- CA
- ZIP
- 93043
- Mailing
- 2451 EASTMAN AVE SUITE 17, OXNARD, CA 93030
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 24
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.405 G02 IV
- Issued
- Jan 23, 2026
- Penalty
- Initial $2,894 · Current $2,894
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws. Roof, Bldg. 1184: On or about December 9th, 2025, and at times prior thereto, employee(s) used a portable power distribution unit to supply power for powered tool(s), the portable power distribution unit did not have strain relief and had exposed wiring. This condition potentially exposed employee(s) to electrical shock and/or fire hazards.
Recent events (1)
- — Z (S) $2894
1926.150 A04
- Issued
- Jan 23, 2026
- Abate by
- Jan 30, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.150(a)(4): Firefighting equipment was not periodically inspected. Roof, bldg. 801: On or about December 9th, 2025, and at times prior thereto, fire extinguisher(s) had not been subjected to their periodic inspection. This condition potentially exposed employee(s) to fire hazard(s).
Recent events (1)
- — Z (O) $0
1926.502 D21
- Issued
- Jan 23, 2026
- Abate by
- Jan 30, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.502(d)(21):Personal fall arrest systems were not inspected prior to each use for wear, damage, and other deterioration, and/or defective components were not removed from service. Roof, bldg. 801: On or about December 9th, 2025, and at times prior thereto, the employer did not ensure that employee(s) inspected Personal fall arrest system(s) prior to each use for wear, damage, and other deterioration, and/or defective components to include fall protection harness/equipment inspections record tags were left blank. This condition potentially exposed employee(s) to fall hazard(s).
Recent events (1)
- — Z (O) $0
More inspections at J Davis Construction Management INC
View J Davis Construction Management INC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348635301.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.