TAMPA, FL ·
OSHA Inspection: BRANDON CONSTRUCTION COMPANY GENERAL CONTRACTORS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of BRANDON CONSTRUCTION COMPANY GENERAL CONTRACTORS, INC. in 2215 SOUTH OCCIDENTAL DR, TAMPA, FL 33629 (NAICS 236115). OSHA activity number 348639212.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Site address
- 2215 SOUTH OCCIDENTAL DR
- City
- TAMPA
- State
- FL
- ZIP
- 33629
- Mailing
- 557 ALTERNATE 19 N., PALM HARBOR, FL 34683
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236115
- Employees
- 20
- Ownership type
- Private (A)
Citations
10 citations on file for this inspection.
1926.20 B02
- Issued
- Jan 27, 2026
- Abate by
- Feb 6, 2026
- Penalty
- Initial $3,972 · Current $2,383 Reduced
General-duty citation text
29 CFR 1926.20(b)(2):The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s). On the roof of a residence, located at 2215 S Occidental Street, Tampa, Florida 33629: On or about 12/9/2025, the employer exposed a subcontractors employees to fall hazards, in that they did not conduct regular safety inspections and correct hazards while performing framing work.
Recent events (2)
- · I (S) $2383.2
- · Z (S) $3972
1926.451 A01
- Issued
- Jan 27, 2026
- Abate by
- Feb 6, 2026
- Penalty
- Initial $3,972 · Current $2,383 Reduced
General-duty citation text
29 CFR 1926.451(a)(1): Each scaffold and/or scaffold component was not capable of supporting, without failure, its own weight and at least 4 times the maximum intended load applied or transmitted to it: On a job made scaffold at a residential home, located at 2215 S Occident Street, Tampa, Florida 33619: On or about 12/9/2025, the employer exposed a subcontractors employees to fall hazards, in that the scaffold was not designed by a qualified person to support at least 4 times the maximum intended weight before performing framing activities.
Recent events (2)
- · I (S) $2383.2
- · Z (S) $3972
1926.451 A06
- Issued
- Jan 27, 2026
- Abate by
- Feb 6, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(a)(6):Scaffolds were not constructed in accordance with the design by a qualified person: a. On a job made scaffold at a residential home, located at 2215 S Occident Street, Tampa, Florida 33619: On or about 12/9/2025, the employer exposed a subcontractors employees to fall hazards, in that the scaffold was not designed by a qualified person before performing framing activities.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 B01
- Issued
- Jan 27, 2026
- Abate by
- Feb 6, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a. On a job made scaffold at a residential home, located at 2215 South Occident Street, Tampa, Florida 33619: On or about 12/9/2025, the employer exposed a subcontractors employees to fall hazards, in that the scaffold platform was not fully planked while performing framing activities.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 F03
- Issued
- Jan 27, 2026
- Abate by
- Feb 6, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a. On a job made scaffold at a residential home, located at 2215 South Occident Street, Tampa, Florida 33619: On or about 12/9/2025, the employer exposed a subcontractors employees to fall hazards, in that an inspection by a competent person was not done before performing framing activities.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 G01
- Issued
- Jan 27, 2026
- Abate by
- Feb 6, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a. On a job made scaffold at a residential home, located at 2215 South Occident Street, Tampa, Florida 33619: On or about 12/9/2025, the employer exposed a subcontractors employees to fall hazards, in that fall protection was not used while performing framing activities.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.451 E01
- Issued
- Jan 27, 2026
- Abate by
- Feb 6, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. a. On a job made scaffold at a residential home, located at 2215 South Occident Street, Tampa, Florida 33619: On or about 12/9/2025, the employer exposed a subcontractors employees to fall hazards, in that a safe access point was not installed before performing framing activities.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.454 A
- Issued
- Jan 27, 2026
- Abate by
- Feb 6, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. a. On a job made scaffold at a residential home, located at 2215 South Occident Street, Tampa, Florida 33619: On or about 12/9/2025, the employer exposed a subcontractors employees to fall hazards, in that employees were not trained to recognize and minimize fall hazards before performing framing activities.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1926.501 B13
- Issued
- Jan 27, 2026
- Abate by
- Feb 6, 2026
- Penalty
- Initial $3,972 · Current $2,383 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a. On the roof at a residential home, located at 2215 South Occident Street, Tampa, Florida 33619: On or about 12/9/2025, the employer exposed a subcontractors employees to fall hazards, in that employees were not using fall protection while performing framing activities.
Recent events (2)
- · I (S) $2383.2
- · Z (S) $3972
1926.1053 B01
- Issued
- Jan 27, 2026
- Abate by
- Feb 6, 2026
- Penalty
- Initial $3,972 · Current $2,383 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a. In the interior of a residential home, located at 2215 South Occident Street, Tampa, Florida 33619: On or about 12/9/2025, the employer exposed a subcontractors employees to fall hazards, in that the ladder used to gain access to the roof did not extend three feet above the upper sloped landing area.
Recent events (2)
- · I (S) $2383.2
- · Z (S) $3972
More inspections at Brandon Construction Company General Contractors, INC.
View Brandon Construction Company General Contractors, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 236115)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348639212.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.