BOISE, ID —
OSHA Inspection: BRIGADE EVENTS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of BRIGADE EVENTS LLC in 7024 SOUTH EISENMAN ROAD, BOISE, ID 83716 (NAICS 323113). OSHA activity number 348645235.
Where did this inspection happen?
- Establishment
- BRIGADE EVENTS LLC
- Site address
- 7024 SOUTH EISENMAN ROAD
- City
- BOISE
- State
- ID
- ZIP
- 83716
- Mailing
- 3681 S. TK AVE., BOISE, ID 83705
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 323113
- Employees
- 8
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.37 A03
- Issued
- Penalty
- Initial $2838.00 · Current $1419.00 Reduced
General-duty citation text
29 CFR 1910.37(a)(3): Exit route(s) were not kept free and unobstructed: (a) South Storage Area: On or about December 16, 2025, employees working in the shop or accessing the breakroom, did not have a clear path to the exit due to stored materials that were blocking the exit door.
Recent events (2)
- — I (S) $1419
- — Z (S) $2838
1910.106 D05 III
- Issued
- Penalty
- Initial $2838.00 · Current $1419.00 Reduced
General-duty citation text
29 CFR 1910.106(d)(5)(iii): The storage of flammable or combustible liquids required and used for the maintenance and operation of building and operation of equipment was not kept in closed metal containers stored in a storage cabinet or in safety cans or in an inside storage room not having a door that opens into that portion of the building used by the public: (a) Washroom and Dark Room Area: On or about December 16, 2025, containers of acetone, isopropyl alcohol, and Rapid Remover were stored on a shelf near other combustible items.
Recent events (2)
- — I (S) $1419
- — Z (S) $2838
1910.134 C02 II
- Issued
- Abate by
- Penalty
- Initial $1702.00 · Current $851.00 Reduced
General-duty citation text
29 CFR 1910.134(c)(2)(ii): The employer did not establish and implement those elements of a written program necessary to ensure that any employee using a respirator voluntarily was medically able to use that respirator, and that the respirator was cleaned, stored, and maintained so that its use does not present a health hazard to the user: (a) Washroom and Dark Room: On or about December 16, 2025, employees voluntarily wore a Honeywell or 3M half-mask elastomeric respirators when using Baselayr Long Lasting emulsion on printing screens in an enclosed area.
Recent events (2)
- — I (S) $851
- — Z (S) $1702
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: (a) Washroom and Dark Room: On or about December 16, 2025, employees voluntarily wore a Honeywell or 3M half-mask elastomeric respirators when using Baselayr Long Lasting emulsion on printing screens in an enclosed area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 K06
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(k)(6): The employer did not provide the basic advisory information on respirators, as presented in Appendix D of 29 CFR 1910.134, in written or oral format to employees who wear respirators when such use was not required by the employer: (a) Washroom and Dark Room: On or about December 16, 2025, employees voluntarily wore a Honeywell or 3M half-mask elastomeric respirators when using Baselayr Long Lasting emulsion on printing screens in an enclosed area.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 G01 IV B
- Issued
- Penalty
- Initial $2270.00 · Current $1135.00 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors: (a) Washroom: On or about December 16, 2025, an extension cord powering equipment in the washroom area had been run through the wall. (b) Screen Printing Area: On or about December 16, 2025, extension cords were run through rafters to provide power for screen printing equipment.
Recent events (2)
- — I (S) $1135
- — Z (S) $2270
1910.37 A04
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.37(a)(4): Safeguard(s) designed to protect employees during an emergency (e.g., sprinkler systems, alarm systems, fire doors, exit lighting), were not in proper working order at all times: a) Breakroom: On December 16, 2025, approximately seven ceiling tiles were missing.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 323113)
CHICAGO, IL—2026-07-08
SOARDIST USA INC. DBA SOARDIST DISPLAYS AND APPAREL
PENNOCK, MN—2026-07-06
111536 - MINNESOTA SCREEN PRINT - EMBROIDERY INC
PENNOCK, MN—2026-07-06
111528 - MINNESOTA SCREEN PRINT - EMBROIDERY INC
NORWALK, CT—2026-07-06
LAX.COM
NORFOLK, VA—2026-07-01
TEGRA GLOBAL
More inspections in ID
BOISE, ID—2026-07-16
RAYMOND MANAGEMENT COMPANY
MERIDIAN, ID—2026-07-15
TRIPLE R CONSTRUCTION LLC
MERIDIAN, ID—2026-07-15
MIRZON CONSTRUCTION LLC
MERIDIAN, ID—2026-07-15
EASTER SEALS - GOODWILL NORTHERN ROCKY MOUNTAINS
NAMPA, ID—2026-07-15
ELITE STEEL ERECTORS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348645235.