Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNITED CONSOLIDATED GROUP, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of UNITED CONSOLIDATED GROUP, INC. in 4669 CHURCH ROAD, CUMMING, GA 30040 (NAICS 238910). OSHA activity number 348648080.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch United Consolidated Group, INC. — free Get an email when a new federal OSHA severe-injury report for United Consolidated Group, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4669 CHURCH ROAD
City
CUMMING
State
GA
ZIP
30040
Mailing
4369 TANNERS CHURCH ROAD BEHIND SETTINGDOWN CHURCH, ELLENWOOD, GA 30294
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
165
Ownership type
A

1 citation on file for this inspection.

1926.652 A01

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
Jan 13, 2026
Penalty
Initial $10,129 · Current $6,077 Reduced

Hazardous substances S777

29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).  a) Excavation located at 4669 Church Road, Cumming, GA 30040: On or about 12/17/2025, the employer exposed employees to cave-in/engulfment hazards while working inside a trench which measured  approximately 6-feet, 8 inches deep by 12 foot, 4-inches wide by 16-feet long, in that an adequate cave-in protection system was not provided to a employees engaged in water tap gate valve installation.