COLORADO SPRINGS, CO —
OSHA Inspection: GREEN PHARM II LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of GREEN PHARM II LLC in 3111 N STONE AVE STE 160, COLORADO SPRINGS, CO 80907 (NAICS 111419). OSHA activity number 348648452.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- GREEN PHARM II LLC
- Site address
- 3111 N STONE AVE STE 160
- City
- COLORADO SPRINGS
- State
- CO
- ZIP
- 80907
- Mailing
- 7615 SLATE CT, COLORADO SPRINGS, CO 80919
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 111419
- Employees
- 18
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.305 G01 IV A
- Issued
- Jun 10, 2026
- Abate by
- Jul 17, 2026
- Penalty
- Initial $3,972 · Current $3,972
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) On or about April 17, 2026, and at times prior, the employer did not ensure that flexible cords in the trimming room were not used as fixed wiring. Flexible cords and power strips were used as power sources for wall mounted fans. (b) On or about April 17, 2026, and at times prior, the employer did not ensure that flexible cords in the curing room were not used as fixed wiring. Flexible cords and power strips were used as power sources for wall mounted fans. This condition could expose employees to the condition of electric shock or result in a fire.
Recent events (1)
- — Z (S) $3972
1910.305 G02 III
- Issued
- Jun 10, 2026
- Abate by
- Jul 17, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws: (a) On or about April 17, 2026, and at times prior, the employer did not ensure that flexible cords in the trimming room were provided strain relief. A surge protector in the trimming room was hung by its flexible cord without strain relief next to the storage room door. (b) On or about April 17, 2026, and at times prior, the employer did not ensure that flexible cords in the curing room were provided strain relief. Surge protectors and multi-receptacle outlets were hung by their flexible cords without strain relief. This condition could expose employees to the condition of electric shock or result in a fire.
Recent events (1)
- — Z (S) $0
1910.334 A03 II
- Issued
- Jun 10, 2026
- Abate by
- Jul 17, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.334(a)(3)(ii): Attachment plugs and receptacles were connected or altered in a manner which prevented proper continuity of the electric equipment grounding conductor at the point where plugs were attached to receptacles: (a) On or about April 17, 2026, and at times prior, employees were exposed to electrical shock hazards in that the charging plug on the scissor lift [SN: 22001274] in grow room 2 did not have a grounding pin.
Recent events (1)
- — Z (S) $0
1926.452 W06 I
- Issued
- Jun 10, 2026
- Abate by
- Jul 17, 2026
- Penalty
- Initial $3,972 · Current $3,972
General-duty citation text
29 CFR 1926.452(w)(6)(i): Employee(s) were allowed to ride on scaffolds when the surface on which the scaffold was moved was not within 3 degrees of level, and/or not free of pits, holes, and obstructions: a) On or about April 17, 2026 and at times prior, employees operating a scissor lift in the cure room were exposed to injuries from tip overs in that the lift was being operated near a 10x10 floor drain in the cure room floor.
Recent events (1)
- — Z (S) $3972
More inspections at Green Pharm II LLC