CLARENCE, NY —
OSHA Inspection: DIMAR MANUFACTURING CORPORATION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DIMAR MANUFACTURING CORPORATION in 10123 MAIN STREET, CLARENCE, NY 14031 (NAICS 332322). OSHA activity number 348651019.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DIMAR MANUFACTURING CORPORATION
- Site address
- 10123 MAIN STREET
- City
- CLARENCE
- State
- NY
- ZIP
- 14031
- Mailing
- 10123 MAIN STREET, CLARENCE, NY 14031
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 181
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.151 C
- Issued
- Feb 13, 2026
- Abate by
- Mar 10, 2026
- Penalty
- Initial $9,045 · Current $5,500 Reduced
General-duty citation text
29 CFR 1910.151(c):Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) On or about 12/16/2026 at 10123 Main Street, Clarence, NY; where employees handle, and are potentially exposed to, a corrosive chemical, GF CLEAN 1052 (potassium hydroxide). ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
- — I (S) $5500
- — Z (S) $9045
1910.147 C06 II
- Issued
- Feb 13, 2026
- Abate by
- Mar 10, 2026
- Penalty
- Initial $5,426 · Current $3,300 Reduced
General-duty citation text
29 CFR 1910.147(c)(6)(ii): Where lockout was used for energy control, the employer did not certify/document that the periodic inspections between the inspector and each authorized employee, of that employee's responsibilities under the energy control procedure being inspected have been performed: a) On or about 12/16/2026, throughout the manufacturing areas; where employees perform servicing and maintenance on machine and equipment such as, but limited to press brakes, laser cutting machines and powder coating lines. The employer did not certify/document the review of each "authorized" employees performing a lockout operation. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $3300
- — Z (S) $5426
1910.145 C03
- Issued
- Feb 13, 2026
- Abate by
- Mar 10, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.145(c)(3):Safety instruction sign(s) were not used where there was a need for general instructions and suggestions relative to safety measure(s): a) On or about 02/05/2026 at the 4280 Research Parkway location; where the noise level in the Grind Room was at, or above 92 decibels, there was no sign requiring hearing protection. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Dimar Manufacturing Corporation
View Dimar Manufacturing Corporation's full OSHA safety record →
More inspections in this industry (NAICS 332322)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348651019.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.