CAMDEN, NJ —
OSHA Inspection: W&W STEEL, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of W&W STEEL, LLC in 2201 MOUNT EPHRAIM AVE., CAMDEN, NJ 08101 (NAICS 332312). OSHA activity number 348651373.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- W&W STEEL, LLC
- Site address
- 2201 MOUNT EPHRAIM AVE.
- City
- CAMDEN
- State
- NJ
- ZIP
- 08101
- Mailing
- 2201 MOUNT EPHRAIM AVE., CAMDEN, NJ 08101
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332312
- Employees
- 6
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.36 D01
- Issued
- Apr 22, 2026
- Abate by
- May 18, 2026
- Penalty
- Initial $4,965 · Current $4,965
General-duty citation text
29 CFR 1910.36(d)(1): Employee(s) were not able to open an exit route door from the inside at all times without keys, tools, or special knowledge: a) 2201 Mt. Ephraim Ave, Camden, NJ - The employer did not ensure that the employees who work in the warehouse were able to open the Northwest side exit route door without any prior action such as removing a carabiner from the hasp, thus exposing employees to emergency egress hazards. This condition was observed on or about December 18, 2025. b) 2201 Mt. Ephraim Ave, Camden, NJ - The employer did not ensure that the employees who work in the warehouse were able to open the Southwest side exit route door without any prior action such as removing a carabiner from the hasp, thus exposing employees to emergency egress hazards. This condition was observed on or about December 18, 2025. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (O) $4965
- — Z (S) $4965
1910.37 A03
- Issued
- Apr 22, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(a)(3): Exit routes were not kept free and unobstructed. Materials or equipment were placed, either permanently or temporarily, within the exit route: a) 2201 Mt. Ephraim Ave, Camden, NJ - Northwest exit door - The employer did not ensure that the exit route to the exit door was free from obstructions such as welding cables, barrels and work stands, thus exposing employees to emergency egress hazards. This condition was observed on or about December 18, 2025. NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.101 B
- Issued
- Apr 22, 2026
- Penalty
- Initial $2,837 · Current $2,837
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in Sec. 1910.6. Section 3.3.1 of the CGA Pamphlet P-1-1965 refers to storing cylinders in accordance with CGA and NFPA standards. The CGA Pamphlet P-1-1991 Section 3.7.4.1 states that "All compressed gas cylinders in service or in storage shall be secured to prevent from falling": a) 2201 Mt. Ephraim Ave, Camden, NJ - The employer did not ensure that compressed gas cylinders in storage were secured from falling, thus exposing employees to fire/explosion hazards. This condition was noted on or about December 18, 2025. NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (2)
- — I (O) $2837
- — Z (S) $2837
1910.253 B04 III
- Issued
- Apr 22, 2026
- Penalty
- Initial $3,547 · Current $3,547
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet or by a noncombustible barrier at least 5 feet high having a fire-resistance rating of at least one half hour: a) 2201 Mt. Ephraim Ave, Camden, NJ - Oxygen compressed gas cylinder was not stored at least 20 feet from acetylene (fuel gas) cylinders. The employer stored a 100 pound oxygen cylinder and two 50 pound acetylene cylinders within approximately 3 feet from each other, thus exposing employees to fire/explosion hazards. NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASE FILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION OR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Recent events (2)
- — I (O) $3547
- — Z (S) $3547
More inspections at W&W Steel, LLC
View W&W Steel, LLC's full OSHA safety record →
More inspections in this industry (NAICS 332312)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348651373.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.