PARIS, IL —
OSHA Inspection: CADILLAC PRODUCTS PACKAGING COMPANY
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CADILLAC PRODUCTS PACKAGING COMPANY in 2005 SOUTH MAIN STREET, PARIS, IL 61944 (NAICS 326112). OSHA activity number 348656117.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CADILLAC PRODUCTS PACKAGING COMPANY
- Site address
- 2005 SOUTH MAIN STREET
- City
- PARIS
- State
- IL
- ZIP
- 61944
- Mailing
- 2005 SOUTH MAIN STREET, PARIS, IL 61944
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326112
- Employees
- 115
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.147 C04 I
- Issued
- May 6, 2026
- Penalty
- Initial $8,513 · Current $5,959 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about December 11, 2025, an employee was exposed to caught-in hazards when performing maintenance and servicing including but not limited to Line 9 - Extruder: Fluff Feed System, and procedures were not developed, documented, and utilized.
Recent events (2)
- — I (S) $5959
- — Z (S) $8513
1910.147 D
- Issued
- May 6, 2026
- Penalty
- Initial $11,916 · Current $8,341 Reduced
General-duty citation text
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6): Employees who performed servicing and maintenance were not required to: (1) Know the type and magnitude of the energy, the hazards of the energy to be controlled, and the method or means to control the energy, (2) Turn off and shut down the machine, (3) Physically locate and operate energy isolating devices in such a manner as to isolate the machine or equipment from the energy source, (4) Affix lockout or tagout devices to each energy isolating device, (5) Prior to starting work on machines that have been locked out or tagged out, verify that isolation and deenergization of the machine or equipment have been accomplished. (6) Prior to starting work on machines that have been locked out or tagged out, verify that isolation and deenergization of the machine or equipment have been accomplished. On or about December 11, 2025, an employee was exposed to caught?in hazards while performing maintenance and servicing activities, including but not limited to work on Line 9 - Extruder: Fluff Feed System. This occurred because the employer did not follow or complete the steps in the sequence required by 29 CFR 1910.147(d)(1)-(6).
Recent events (2)
- — I (S) $8341
- — Z (S) $11916
1910.219 C02 I
- Issued
- May 6, 2026
- Abate by
- May 29, 2026
- Penalty
- Initial $8,513 · Current $5,950 Reduced
General-duty citation text
29 CFR 1910.219(c)(2)(i): All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting: On or about December 11, 2025, employees working around Line #9 were exposed to caught-in hazards because the rotating shaft at the rear of the extruder was not adequately guarded.
Recent events (2)
- — I (S) $5950
- — Z (S) $8513
1910.305 B01 II
- Issued
- May 6, 2026
- Abate by
- May 29, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed: On or about December 11, 2025, employees were exposed to electrical shock when using the snap switch, on the side of Line 9. The snap switch box had an opening and was not effectively closed to prevent contact to exposed conductors.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Cadillac Products Packaging Company
View Cadillac Products Packaging Company's full OSHA safety record →
More inspections in this industry (NAICS 326112)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348656117.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.