Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: RCG REMODELING INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RCG REMODELING INC. in 1350 GLENCOE AVE, HIGHLAND PARK, IL 60035 (NAICS 238160). OSHA activity number 348658881.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch RCG Remodeling INC. — free Get an email when a new federal OSHA severe-injury report for RCG Remodeling INC. is published. One employer, no account, unsubscribe in one click.
Establishment
RCG REMODELING INC.
Site address
1350 GLENCOE AVE
City
HIGHLAND PARK
State
IL
ZIP
60035
Mailing
12 6TH AVE., ARLINGTON HEIGHTS, IL 60005
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

5 citations on file for this inspection.

1926.150 C01 VI

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 3, 2026
Abate by
Mar 27, 2026
Penalty
Initial $4,256 · Current $4,256
29 CFR 1926.150(c)(1)(vi): A fire extinguisher, rated not less than 10B, was not provided within 50 feet of wherever more than 5 gallons of flammable or combustible liquids or 5 pounds of flammable gas were being used on the jobsite:  a) On or about December 22, 2025, a fire extinguisher was not provided where employees were using a 20-pound propane tank to fuel a roofing torch.  In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
  • — Z (S) $4256

1926.501 B13

Serious Gravity 10 1 instance 3 exposed
Issued
Mar 3, 2026
Penalty
Initial $4,965 · Current $4,965
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   a) On or about December 22, 2025, employees were exposed to fall hazards while working without fall protection from a pitched roof having a ground to eave height up to approximately 23.1 feet.  No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (S) $4965

1926.502 D06 I

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 3, 2026
Penalty
Initial $4,965 · Current $4,965
29 CFR 1926.502(d)(6)(i): A snaphook not designed for such use was engaged directly to webbing, rope or wire rope:  a) On or about December 22, 2025, employees were using a personal fall arrest life line that had its locking snaphook engaged back onto the life line rope.  No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (S) $4965

1926.502 D15

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 3, 2026
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15): Anchorages used for attachment of personal fall arrest equipment were not independent of any anchorage being used to support or suspend platforms and/or were not capable of supporting at least 5,000 pounds (22.2 kN) per employee:  a) On or about December 22, 2025, anchorages being used for attachment of personal fall arrest equipment were not installed so that they would be capable of supporting at least 5,000 pounds per employee attached.  No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (S) $0

1926.502 D17

Serious Gravity 10 1 instance 1 exposed
Issued
Mar 3, 2026
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(17): The attachment point of the body harness was not located in the center of the wearer's back near shoulder level, or above the wearer's head:    a) On or about December 22, 2025, the front nylon straps of body harnesses were used as attachment points for fall protection on pitched roof surfaces.  No abatement certification or documentation required for this violation.
Recent events (1)
  • — Z (S) $0

View RCG Remodeling INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348658881.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.