HARRISON, OH —
OSHA Inspection: ABCON AUTOMATION, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of ABCON AUTOMATION, INC. in 10991 ST RT 128, HARRISON, OH 45030 (NAICS 238210). OSHA activity number 348659053.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ABCON AUTOMATION, INC.
- Site address
- 10991 ST RT 128
- City
- HARRISON
- State
- OH
- ZIP
- 45030
- Mailing
- 10991 ST RT 128, HARRISON, OH 45030
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238210
- Employees
- 4
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.22 B
- Issued
- Feb 4, 2026
- Abate by
- Mar 24, 2026
- Penalty
- Initial $3,547 · Current $3,547
General-duty citation text
29 CFR 1910.22(b):(b) Loads. The employer must ensure that each walking-working surface can support the maximum intended load for that surface. a)On or about December 20, 2025, the employer failed to ensure that the interstitial ceiling panels used as a walking-working surface could support the maximum intended load for that surface. Employees were performing work activities such as installing an HVAC motor in the interstitial space above the drop ceiling, while standing on top of a suspended ceiling of Mesa insulated metal panels. A panel failed and an employee fell approximately 20 to the concrete floor below.
Recent events (2)
- — I (S) $3547
- — Z (S) $3547
1910.22 D03
- Issued
- Feb 4, 2026
- Abate by
- Mar 24, 2026
- Penalty
- Initial $3,547 · Current $0 Reduced
General-duty citation text
29 CFR 1910.22(d)(3):(3) When any correction or repair involves the structural integrity of the walking-working surface, a qualified person performs or supervises the correction or repair. a)On our about December 20, 2025, the employer did not ensure that a qualified person performed or supervised repair work affecting the structural integrity of an interstitial walking working surface. Employees, performing work activities, including installing an HVAC motor in the interstitial space above the drop ceiling, which required the opening and repairing of the walking working surface were exposed to a fall hazard of approximately 20 feet to the production floor below.
Recent events (2)
- — I (S) $0
- — Z (S) $3547
1910.28 B03 I
- Issued
- Feb 4, 2026
- Abate by
- Mar 24, 2026
- Penalty
- Initial $4,965 · Current $4,965
General-duty citation text
29 CFR 1910.28(b)(3)(i):(3) Holes. The employer must ensure: (i) Each employee is protected from falling through any hole (including skylights) that is 4 feet (1.2 m) or more above a lower level by one or more of the following: (A)Covers; (B)Guardrail systems; (C)Travel restraint systems; or (D)Personal fall arrest systems. a)On or about December 20, 2025, the employer failed to ensure employees were protected from falling through an opening in the ceiling approximately 20 feet above the production floor while performing millwright activities, including hoisting and installing a motor. Employees were standing near and working around a 12-foot section of ceiling panel that had been removed without any cover, guardrail system, or properly anchored fall protection. As a result, employees were exposed to a fall hazard of approximately 20 feet.
Recent events (2)
- — I (S) $4965
- — Z (S) $4965
1910.140 C20
- Issued
- Feb 4, 2026
- Abate by
- Mar 24, 2026
- Penalty
- Initial $4,965 · Current $0 Reduced
General-duty citation text
29 CFR 1910.140(c)(20):(20) Ropes, belts, lanyards, lifelines, and harnesses used for personal fall protection must be protected from being cut, abraded, melted, or otherwise damaged. a) On or about December 20, 2025, the employer failed to ensure that ropes, belts, lanyards, lifelines, and harnesses used for personal fall protection were protected from being cut, abraded, or otherwise damaged. Anchor points utilized by employees preforming millwright activities in an interstitial space above a dropped ceiling were wrapped directly around steel structural support beams in the roof without any protective covers or sleeves to prevent damage. As a result, employees were exposed to fall hazards at approximately 20 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $4965
More inspections in this industry (NAICS 238210)
More inspections in OH
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348659053.