Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: COAST GUARD EXCHANGE (CGX)

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of COAST GUARD EXCHANGE (CGX) in 1664 WEEKSVILLE ROAD, BLDG 990, ELIZABETH CITY, NC 27909 (NAICS 928110). OSHA activity number 348671827.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coast Guard Exchange (CGX) — free Get an email when a new federal OSHA severe-injury report for Coast Guard Exchange (CGX) is published. One employer, no account, unsubscribe in one click.
Site address
1664 WEEKSVILLE ROAD, BLDG 990
City
ELIZABETH CITY
State
NC
ZIP
27909
Mailing
1664 WEEKSVILLE ROAD, BLDG 990, ELIZABETH CITY, NC 27909
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
928110
Employees
10
Ownership type
D

3 citations on file for this inspection.

1910.22 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 5, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.22(a)(1): All places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition.  On or about January 6, 2026, the employer did not to keep the workplace clean and orderly, employees were exposed to slip/trip hazards
Recent events (1)
  • — Z (S) $0

1910.37 A03

Serious Gravity 5 1 instance 1 exposed
Issued
Feb 5, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.37(a)(3):Exit routes must be free and unobstructed. No materials or equipment may be placed, either permanently or temporarily, within the exit route. The exit access must not go through a room that can be locked, such as a bathroom, to reach an exit or exit discharge, nor may it lead into a dead-end corridor. Stairs or a ramp must be provided where the exit route is not substantially level.  On or about January 6, 2026, the employer did not ensure that exit routes were free and unobstructed. An extension cord was placed across an exit door/exit access, obstructing the means of egress and exposing employees to delayed evacuation or injury during an emergency.
Recent events (1)
  • — Z (S) $0

1910.303 B02

Serious Gravity 10 1 instance 1 exposed
Issued
Feb 5, 2026
Abate by
May 6, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2):Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.  On or about January 6, 2026, commercial refrigerators  were plugged into surge suppressors (power strips) instead of being connected directly to permanent wall receptacles.  employees were exposed to serious electrical hazards, including overheating, electrical failure, or even fire.
Recent events (1)
  • — Z (S) $0