OSHA Inspection: SMV CONSTRUCTION CORP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SMV CONSTRUCTION CORP in 22700 NEBULA LANE, LAND O LAKES, FL 34638 (NAICS 238170). OSHA activity number 348674490.

Watch SMV Construction Corp — free Get an email when a new federal OSHA severe-injury report for SMV Construction Corp is published. One employer, no account, unsubscribe in one click.
Site address
22700 NEBULA LANE
City
LAND O LAKES
State
FL
ZIP
34638
Mailing
8026 CHIKASAW LANE, PORT RICHEY, FL 34668
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238170
Employees
5
Ownership type
A

7 citations on file for this inspection.

1926.451 C02 I

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3972.00 · Current $2780.00 Reduced
29 CFR  1926.451(c)(2)(i):Footings were not level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement:  On a Pump Jack Scaffold  at a residential home, located at 22700 Nebula Lane, Land O Lakes, Florida 33668: On or about 1/8/2026, the employer exposed employees to fall hazards, in that The footings on the scaffold were not capable of supporting the load without settling,  while performing siding work.
Recent events (2)
  • — I (S) $2780.4
  • — Z (S) $3972

1926.451 F03

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:   On a Pump Jack Scaffold  at a residential home, located at 22700 Nebula Lane, Land O Lakes, Florida 33668: On or about 1/8/2026, the employer exposed employees to fall hazards, in that a competent person did not do an inspection of the scaffold before performing siding work.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:   On a Pump Jack Scaffold  at a residential home, located at 22700 Nebula Lane, Land O Lakes, Florida 33668: On or about 1/8/2026, the employer exposed employees to fall hazardsof 12 feet, in that fall protection was not used while performing siding work while on the pump jack scaffolding
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 J02

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary.   On a Pump Jack Scaffold  at a residential home, located at 22700 Nebula Lane, Land O Lakes, Florida 33668: On or about 1/8/2026, the employer exposed employees to fall hazards, in that the base poles were not secured to the building while performing siding work.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards.   On a Pump Jack Scaffold  at a residential home, located at 22700 Nebula Lane, Land O Lakes, Florida 33668: On or about 1/8/2026, the employer exposed employees to fall hazards, in that training was not provided on how to recognize and minimize fall hazards before performing siding work from the scaffolding.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3972.00 · Current $2780.00 Reduced
29 CFR  1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):    On the front roof at a residential home, located at 22700 Nebula Lane, Land O Lakes, Florida 33668: On or about 1/8/2026, the employer exposed employees to fall hazards over 12 feet, in that fall protection was not used while performing siding work while standing on the roof of the home.
Recent events (2)
  • — I (S) $2780.4
  • — Z (S) $3972

1926.503 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards:   On the front roof a residential home, located at 22700 Nebula Lane, Land O Lakes, Florida 33668: On or about 1/8/2026, the employer exposed employees to fall hazards, in that training was not provided on how to recognize and minimize fall hazards before performing siding work.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348674490.