HANOVER, PA —
OSHA Inspection: CUSTOM WALLS, INC.
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of CUSTOM WALLS, INC. in 118 - 120 FREDERICK STREET, HANOVER, PA 17331 (NAICS 238110). OSHA activity number 348678038.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CUSTOM WALLS, INC.
- Site address
- 118 - 120 FREDERICK STREET
- City
- HANOVER
- State
- PA
- ZIP
- 17331
- Mailing
- 175 HOLSTEIN DRIVE, HANOVER, PA 17331
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238110
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.501 B01
- Issued
- Feb 20, 2026
- Abate by
- Mar 11, 2026
- Penalty
- Initial $3,972 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(1):Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) Jobsite: 118 Frederick Street, Hanover, PA. On or about January 9, 2026, at the demolition construction site employees walking and working on elevated concrete formwork were exposed to a fall hazard of approximately 7 feet to a lower level without the use of a fall protection system. b) Jobsite: 118 Frederick Street, Hanover, PA. On or about January 9, 2026, an employee was observed walking along the top of a concrete form wall without any form of fall protection, exposing them to a fall hazard of approximately 13 feet. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $3972
1926.651 C02
- Issued
- Feb 20, 2026
- Abate by
- Mar 11, 2026
- Penalty
- Initial $3,405 · Current $9,600
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) Jobsite: 118 Frederick Street, Hanover, PA. On or about January 9, 2026, employees were working in a trench approximately 13 feet deep and were not provided with a safe means of egress. The ladder present was not positioned to provide a usable means of egress and did not extend to the top of the trench, exposing the employees to a caught-in or struck-by hazard. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $9600
- — Z (S) $3405
1926.651 L
- Issued
- Feb 20, 2026
- Abate by
- Mar 11, 2026
- Penalty
- Initial $2,838 · Current $0 Reduced
General-duty citation text
29 CFR 1926.651(l):Guardrails complying with 1926.502(b) were not provided where walkways were 6 feet (1.8m) or more above lower levels: a) Jobsite: 118 Frederick Street, Hanover, PA. On or about January 9, 2026, an employee crossed over an approximately 13-foot-deep excavated basement by walking on a wood plank used as a bridge from the blacktop surface to the top of a concrete form wall. The walkway was not provided with guardrails, exposing the employee to a fall hazard of approximately 13 feet to the lower level. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (S) $0
- — Z (S) $2838
1926.652 A01
- Issued
- Feb 20, 2026
- Abate by
- Mar 11, 2026
- Penalty
- Initial $3,972 · Current $0 Reduced
General-duty citation text
29 CFR 1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). a) Jobsite: 118 Frederick Street, Hanover, PA. On or about January 9, 2026, employees installing foundation wall concrete forms were working inside a straight cut trench approximately 13 feet deep without cave-in protection, exposing employees to an engulfment hazard. Abatement certification and documentation required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement. Abatement documentation shall include documents demonstrating that abatement is complete, such as evidence of the purchase or repair of equipment, photograph or video evidence of abatement or other written records.
Recent events (2)
- — I (S) $0
- — Z (S) $3972
1926.701 B
- Issued
- Feb 20, 2026
- Abate by
- Mar 11, 2026
- Penalty
- Initial $2,270 · Current $0 Reduced
General-duty citation text
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement: a) Jobsite: 118 Frederick Street, Hanover, PA. On or about January 9, 2026, employees installing concrete foundation walls were exposed to impalement hazards from nine unguarded vertical reinforcing steel bars. b) Jobsite: 118 Frederick Street, Hanover, PA. On or about January 9, 2026, employees working on walking/working surface walls were exposed to impalement hazards from nine unguarded vertical reinforcing steel bars. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and state employees and their representatives were informed of this abatement.
Recent events (2)
- — I (O) $0
- — Z (S) $2270
More inspections at Custom Walls, INC.
View Custom Walls, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238110)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348678038.