ROCKWOOD, PA —
OSHA Inspection: ASSA ABLOY ACCESSORIES AND DOOR CONTROL GROUP, INC.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of ASSA ABLOY ACCESSORIES AND DOOR CONTROL GROUP, INC. in 300 MAIN STREET, ROCKWOOD, PA 15557 (NAICS 332510). OSHA activity number 348679796.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ASSA ABLOY ACCESSORIES AND DOOR CONTROL GROUP, INC.
- Site address
- 300 MAIN STREET
- City
- ROCKWOOD
- State
- PA
- ZIP
- 15557
- Mailing
- P.O. BOX 79, ROCKWOOD, PA 15557
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332510
- Employees
- 242
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.95 C01
- Issued
- May 4, 2026
- Penalty
- Initial $10,641 · Current $6,400 Reduced
8111
General-duty citation text
29 CFR 1910.95(c)(1): A continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (n) was not instituted when employee noise exposures equaled or exceeded an 8-hour time-weighted average sound level (TWA) of 85 dBA: a) In the Facility, on or about February 19, 2026 - The employer did not institute a continuing effective hearing conservation program when employee noise exposures exceeded an 8-hour time-weighted average sound level of 85 dBA. An employee designated as a Saw Operator was exposed to noise at a level of 67.9% of the allowable limit during a 219 minute sampling period on February 19, 2026. This exposure is equivalent to a sound level of 87.2 dBA for the dose and time of employee exposure and is 1.36 times in excess of the 85 dBA action level (50%) at which the hearing conservation program is required.
Recent events (2)
- — I (S) $6400
- — Z (S) $10641
1910.95 G03
- Issued
- May 4, 2026
- Penalty
- Initial $0 · Current $0
8111
General-duty citation text
29 CFR 1910.95(g)(3): Audiometric tests were not performed by a licensed or certified audiologist, otolaryngologist, or other physician or, by a technician who is certified by the Council of Accreditation in Occupational Hearing Conservation: a) In the Facility, on or about February 19, 2026 - The employer did not ensure audiometric tests were performed by a licensed or certified audiologists, otolaryngologist, or other physician or by a technician who is certified by the Council of Accreditation in Occupational Hearing Conservation. (See description of employee noise exposure in Citation 1, Item 1a).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.95 G07 I
- Issued
- May 4, 2026
- Penalty
- Initial $0 · Current $0
8111
General-duty citation text
29 CFR 1910.95(g)(7)(i): Each employee's annual audiogram was not compared to that employee's baseline audiogram to determine if the audiogram is valid and if a standard threshold shift as defined in 29 CFR 1910.95(g)(10) has occurred: a) In the Facility, on or about February 19, 2026 - The employer did not compare each employee's annual audiogram to that employee's baseline audiogram. (See description of employee noise exposure in Citation 1, Item 1a).
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.157 C01
- Issued
- May 4, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: a) In the Aluminum Area, on or about January 8, 2026 - The employer did not ensure a Class D Combustible Metals Fire Extinguisher was mounted and readily accessible.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1026 L02 II
- Issued
- May 4, 2026
- Penalty
- Initial $0 · Current $0
0689
General-duty citation text
29 CFR 1910.1026(l)(2)(ii): The employer did not make a copy of the Chromium (VI) standard, 29 CFR 1910.1026, readily available to all employees who were exposed to chromium (VI): a) In the Facility, on or about February 19, 2026 - The employer did not make a copy of the Chromium (VI) standard readily available to employees who were exposed to chromium (VI).