SAN ANTONIO, TX ·
OSHA Inspection: D & D POWER
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of D & D POWER in 4828 SINCLAIR ROAD, SAN ANTONIO, TX 78222 (NAICS 532490). OSHA activity number 348680679.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- D & D POWER
- Site address
- 4828 SINCLAIR ROAD
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78222
- Mailing
- 4828 SINCLAIR ROAD, SAN ANTONIO, TX 78222
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 532490
- Employees
- 9
- Ownership type
- Private (A)
Citations
7 citations on file for this inspection.
1910.135 A01
- Issued
- Apr 9, 2026
- Abate by
- Apr 29, 2026
- Penalty
- Initial $5,296 · Current $3,178 Reduced
General-duty citation text
29 CFR 1910.135(a)(1): The employer did not ensure that each affected employee wear a protective helmet when working in areas where there is a potential for injury to the head from falling objects. On or about January 9, 2026, employees were utilizing the host crane to lift and move equipment and materials without utilizing head protection.
Recent events (2)
- · I (S) $3177.6
- · Z (S) $5296
1910.184 C01
- Issued
- Apr 9, 2026
- Penalty
- Initial $5,296 · Current $3,178 Reduced
General-duty citation text
29 CFR 1910.184(c)(1): Sling(s) that were damaged or defective were used. On or about January 9, 2026, employees were utilizing worn and damaged slings to lift equipment and material within the hoist area.
Recent events (2)
- · I (S) $3177.6
- · Z (S) $5296
1910.212 B
- Issued
- Apr 9, 2026
- Penalty
- Initial $3,972 · Current $2,383 Reduced
General-duty citation text
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving. On or about January 9, 2026, employees were utilizing a drill press designed for a fixed location and not securely anchored to prevent walking or moving.
Recent events (2)
- · I (S) $2383.2
- · Z (S) $3972
1910.215 A04
- Issued
- Apr 9, 2026
- Abate by
- Apr 29, 2026
- Penalty
- Initial $3,972 · Current $2,383 Reduced
General-duty citation text
29 CFR 1910.215(a)(4): Grinding machinery was not used with work rest(s) to support offhand grinding work. On or about January 9, 2026, employees were utilizing a bench grinder without rest supports installed to perform grinding work.
Recent events (2)
- · I (S) $2383.2
- · Z (S) $3972
1910.215 B09
- Issued
- Apr 9, 2026
- Abate by
- Apr 29, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch. On or about January 9, 2026, and at times prior thereto, employees were utilizing a bench grinder to perform grinding work without the tongue guard exceeding on fourth inch from the abrasive wheel.
Recent events (2)
- · I (S) $0
- · Z (S) $0
1910.253 B02 II
- Issued
- Apr 9, 2026
- Penalty
- Initial $5,296 · Current $3,178 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior. On or about January 9, 2026, employees stored an oxygen cylinder unsecured, next to a passageway, and near combustible wood material.
Recent events (2)
- · I (S) $3177.6
- · Z (S) $5296
1910.305 G01 IV
- Issued
- Apr 9, 2026
- Penalty
- Initial $5,296 · Current $3,178 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv): Flexible cords and/ or cables were used for purposes prohibited by paragraphs (A) through (F) of 29 CFR 1910.305(g)(1)(iv)(a). On or about January 9, 2026, employees were utilizing an extension cord as permanent wiring which was ran from the degreaser area through a doorway and behind an unused spray booth.
Recent events (2)
- · I (S) $3177.6
- · Z (S) $5296
More inspections in this industry (NAICS 532490)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348680679.