SHIPPENSBURG, PA ·
OSHA Inspection: NICHE ELECTRONICS
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of NICHE ELECTRONICS in 201 DYKEMAN ROAD, SHIPPENSBURG, PA 17257 (NAICS 334419). OSHA activity number 348692682.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NICHE ELECTRONICS
- Site address
- 201 DYKEMAN ROAD
- City
- SHIPPENSBURG
- State
- PA
- ZIP
- 17257
- Mailing
- 201 DYKEMAN ROAD, SHIPPENSBURG, PA 17257
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334419
- Employees
- 45
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.134 C01
- Issued
- Jun 25, 2026
- Abate by
- Jul 30, 2026
- Penalty
- Initial $6,620 · Current $6,620
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use. a) 201 Dykeman Road, Shippensburg, PA 17257 - On or about January 15, 2026, the employer did not establish or implement a respiratory protection programs for employees required to wear the 3M Half-Face respirator when cleaning out the Wave Solder Machine. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- · Z (S) $6620
1910.134 E01
- Issued
- Jun 25, 2026
- Abate by
- Jul 30, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace. a) 201 Dykeman Road, Shippensburg, PA 17257 - On or about January 15, 2026, the employer did not provide employees required to wear the 3M Half-Face respirator when cleaning the Wave Solder Machine with a medical evaluation prior to wearing the respirator. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- · Z (S) $0
1910.134 F01
- Issued
- Jun 25, 2026
- Abate by
- Jul 30, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting facepiece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT). a) 201 Dykeman Road, Shippensburg, PA 17257 - On or about January 15, 2026, the employer did not ensure employees passed a respirator fit test prior to requiring the use of the 3M Half-Face respirator when cleaning the Wave Solder Machine. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- · Z (S) $0
1910.134 K01
- Issued
- Jun 25, 2026
- Abate by
- Jul 30, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(k)(1): The employer did not provide effective training that covered the required elements in 29 CFR 1910.134(k)(1)(i) - (vii): a) 201 Dykeman Road, Shippensburg, PA 17257 - On or about January 15, 2026, the employer did not provide respiratory protection training to employees that were required to wear the 3M Half-Face respirator when cleaning the Wave Solder Machine. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- · Z (S) $0
1910.37 E
- Issued
- Jun 25, 2026
- Abate by
- Jul 22, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(e): Employer did not install and maintain an operable employee alarm system that had a distinctive signal to warn employees of fire or other emergencies. a) 201 Dykeman Road, Shippensburg, PA 17257 - On or about January 15, 2026, the employer had not developed or installed an operable employee alarm system that had a distinctive signal to warn employees of fire or other emergencies. Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
- · Z (O) $0
More inspections in this industry (NAICS 334419)
More inspections in PA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348692682.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.