SANFORD, FL ·
OSHA Inspection: OMEGA MEDICAL IMAGING, LLC
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of OMEGA MEDICAL IMAGING, LLC in 3400 SAINT JOHNS PARKWAY SUITE 1020, SANFORD, FL 32771 (NAICS 334510). OSHA activity number 348693052.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- OMEGA MEDICAL IMAGING, LLC
- Site address
- 3400 SAINT JOHNS PARKWAY SUITE 1020
- City
- SANFORD
- State
- FL
- ZIP
- 32771
- Mailing
- 3400 SAINT JOHNS PARKWAY SUITE 1020, SANFORD, FL 32771
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334510
- Employees
- 50
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.134 C01
- Issued
- May 15, 2026
- Penalty
- Initial $6,621 · Current $3,973 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program with worksite-specific procedures in any workplace where respirators were necessary to protect the health of the employee or whenever respirators were required by the employer. a. On or about January 15, 2026, in the painting and welding department: employees were exposed to respiratory hazards, in that, the employer failed to establish and implement a written respiratory protection program with worksite-specific procedures for employees using Draeger - X-plore 5500 Full Face Mask respirators during various operations.
Recent events (2)
- · I (S) $3972.6
- · Z (S) $6621
1910.134 F01
- Issued
- May 15, 2026
- Abate by
- Jun 11, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph: a. On or about January 15, 2026, in the painting and welding department: employees were exposed to respiratory hazards while wearing Draeger - X-plore 5500 Full Face respirator, in that, the employees had not been fit tested to wear a respirator.