WYOMING, DE —
OSHA Inspection: TOP MAN ROOFING, LLC
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of TOP MAN ROOFING, LLC in 29 FRONT STREET, WYOMING, DE 19934 (NAICS 238160). OSHA activity number 348695651.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TOP MAN ROOFING, LLC
- Site address
- 29 FRONT STREET
- City
- WYOMING
- State
- DE
- ZIP
- 19934
- Mailing
- 13 W COUNTRY LANE, NEWARK, DE 19702
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.416 A01
- Issued
- Jan 30, 2026
- Penalty
- Initial $5,107 · Current $5,107
General-duty citation text
29 CFR 1926.416(a)(1):No employer shall permit an employee to work in such proximity to any part of an electric power circuit that the employee could contact the electric power circuit in the course of work, unless the employee is protected against electric shock by deenergizing the circuit and grounding it or by guarding it effectively by insulation or other means. a) 29 Front Street, Wyoming, DE, 19934 (roof) On or about 1/15/2026 - Employees were exposed to electrical shock hazards when the air compressor looped around the service drop of the residence. This could potentially create a shock hazard when employees were required to untangle the lines from the service drop.
Recent events (2)
- — I (S) $5107
- — Z (S) $5107
1926.501 B04
- Issued
- Jan 30, 2026
- Penalty
- Initial $5,107 · Current $5,107
General-duty citation text
29 CFR 1926.501(b)(4): Each employee on walking/working surfaces shall be protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. a) 29 Front Street, Wyoming, DE, 19934 (roof) On or about 1/15/2026: Employees were exposed to a fall hazard when working at elevations greater than 6 feet above grade while working on a residential roof with unguarded skylights.
Recent events (2)
- — I (S) $5107
- — Z (S) $5107
1926.503 A01
- Issued
- Jan 30, 2026
- Abate by
- Feb 26, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(a)(1): The employer did not provide a training program for each employee potentially exposed to fall hazards to enable each employee to recognize the hazards of falling and the procedures to be followed in order to minimize these hazards: a) 29 Front Street, Wyoming, DE, 19934 (roof): On or about 1/15/2026: Employees performing roofing activity on a residential structure were exposed to fall hazards approximately 12 feet above grade without protection in any direction and had not received the required training.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.503 C03
- Issued
- Jan 30, 2026
- Abate by
- Feb 26, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.503(c)(3): Inadequacies in and affected employee's knowledge or use of fall protection systems were equipment indicate that the employee has not retained the requisite understanding or skill. a) 29 Front Street, Wyoming, DE, 19934 (roof) On or about 1/15/2026: during roofing activities, the employer did not ensure employees used appropriate fall protection systems/devices when exposed to fall hazards of at least approximately 12 feet.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B01
- Issued
- Jan 30, 2026
- Penalty
- Initial $5,107 · Current $5,107
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a) On 1/15/2026 at 29 Front Street, Wyoming, De - Employees were exposed to fall hazards when the employer failed to ensure that a minimum of three ladder rungs were above the upper landing surface. Employees utilized the ladder with one rung above the roof line exposing employees to falls.
Recent events (2)
- — I (S) $5107
- — Z (S) $5107
1926.1060 A
- Issued
- Jan 30, 2026
- Abate by
- Feb 26, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards. a) 29 Front Street, Wyoming, DE, 19934: On or about 1/15/2026: the employer failed to provide training on proper ladder use. Employees had erected a Werner aluminum ladder improperly for access to the roof level, for roofing activities approximately 12 feet above grade.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.501 B13
- Issued
- Jan 30, 2026
- Penalty
- Initial $10,215 · Current $10,215
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b) a) 29 Front Street, Wyoming, DE, 19934 (roof) On or about 1/15/2026, the employer failed to provide a guardrail system, safety net systems, or personal fall arrest systems exposing employees to unprotected sides and edges. The Top Man Roofing, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard 1926.501(b)(11), which was contained in OSHA inspection number 1760309, citation number 1, item number 2 and was affirmed as a final order on 1-29-2025, with respect to a workplace located at 4744 Summit Bridge Rd. Middletown, DE 19709: (Roof).
Recent events (2)
- — I (R) $10215
- — Z (R) $10215
More inspections at TOP MAN Roofing, LLC
View TOP MAN Roofing, LLC's full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in DE
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348695651.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.