OSHA Inspection: SCANDIA MOTEL LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SCANDIA MOTEL LLC in 400 NORTH 3RD STREET, MCCALL, ID 83638 (NAICS 721110). OSHA activity number 348699711.

Watch Scandia Motel LLC — free Get an email when a new federal OSHA severe-injury report for Scandia Motel LLC is published. One employer, no account, unsubscribe in one click.
Establishment
SCANDIA MOTEL LLC
Site address
400 NORTH 3RD STREET
City
MCCALL
State
ID
ZIP
83638
Mailing
400 NORTH 3RD STREET, MCCALL, ID 83638
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
721110
Employees
3
Ownership type
A

11 citations on file for this inspection.

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2270.00 · Current $1589.00 Reduced
29 CFR  1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a) Maintenance Room: On January 21, 2026, an employee used an Admiral 12' Dual-bevel sliding compound miter saw Serial # 370441932 which did not have the lower portion of the guard attached.
Recent events (2)
  • — I (S) $1589
  • — Z (S) $2270

1910.303 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1702.00 · Current $1191.00 Reduced
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  a)Laundry Room: On January 21, 2026, a battery charger was plugged into a 6 outlet surge protector which was plugged into an extension cord, which was then plugged into a 110v electrical outlet.  Note: Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1191.4
  • — Z (S) $1702

1910.305 B02 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2838.00 · Current $1987.00 Reduced
29 CFR  1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:   a) Maintenance Room: On January 21, 2026, the junction box was missing the cover exposing live wires.  NOTE: Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1986.6
  • — Z (S) $2838

1910.305 C04

Serious Gravity 5 2 instances 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(c)(4): Snap switches mounted in boxes did not have faceplates installed so as to completely cover the opening and seat against the finished surface.    a) Laundry Room: On January 21, 2026, the double-gang switch did not have a faceplate.  b) Maintenance Room: On January 21, 2026, the double-gang switch did not have a faceplate.  NOTE: Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $3405.00 · Current $2384.00 Reduced
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure:  a) Laundry Room: On January 21, 2026, a flexible cord was running unprotected from a metal  junction box along the floor to an outlet box attached to the wall.   Note: Abatement certification is required for this item.
Recent events (2)
  • — I (S) $2383.5
  • — Z (S) $3405

1910.305 G01 IV B

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors:  a) Maintenance Room, On January 21, 2026: an extension cord supplying 110v power to a junction box was running through a hole in the wall and plugged into an outlet in the adjacent room.  NOTE: Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.305(g)(2)(iii): Flexible cords were not connected to devices and fittings so that tension would not be transmitted to joints or terminal screws:  a)Laundry Room: On January 21, 2026, the cable jacket of the cord plugged into an outlet had separated from the strain relief fitting, exposing the conductors.  Note: Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 E01

Serious Gravity 1 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $1702.00 · Current $1191.00 Reduced
29 CFR  1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program that included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii):   (a) On January 21, 2026, employees performed cleaning and maintenance task using various  chemicals  including but not limited to, Varathune Premium Fast Dry Wood Stain and Rust-oleum spray paint.  Note: Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1191.4
  • — Z (S) $1702

1910.1200 G08

Serious Gravity 1 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(g)(8):   The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work  shift to employees when they were in their work area(s)  (a) On January 21, 2026, employees performed cleaning and maintenance task using various chemicals  including but not limited to, Varathune Premium Fast Dry Wood Stain and Rust-oleum spray paint.  Note: Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1200 H01

Serious Gravity 1 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  (a) On January 21, 2026, employees performed cleaning and maintenance task using various chemicals  including but not limited to, Varathune Premium Fast Dry Wood Stain and Rust-oleum spray paint.  Note: Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.157 E03

Other-than-serious 2 instances 8 exposed
Issued
Abate by
Penalty
Initial $319.00 · Current $223.00 Reduced
29 CFR  1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check:  a) Outside Main Office: On January 21, 2026, the annual fire extinguisher inspection was last conducted in January 2022.  b) Outside Maintenance Room: On January 21, 2026, the annual fire extinguisher inspection was last conducted in June 2015.  Note: Abatement certification is required for this item.
Recent events (2)
  • — I (O) $223.3
  • — Z (O) $319

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348699711.