OSHA Inspection: RP&YA CONSTRUCTION, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of RP&YA CONSTRUCTION, LLC in 9664 FORD AVE., RICHMOND HILL, GA 31324 (NAICS 238130). OSHA activity number 348700527.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rp&Ya Construction, LLC — free Get an email when a new federal OSHA severe-injury report for Rp&Ya Construction, LLC is published. One employer, no account, unsubscribe in one click.
Site address
9664 FORD AVE.
City
RICHMOND HILL
State
GA
ZIP
31324
Mailing
800 QUACCO RD. LOT 114, SAVANNAH, GA 31419
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

2 citations on file for this inspection.

1926.501 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 30, 2026
Penalty
Initial $2,270 · Current $1,362 Reduced
29 CFR  1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.  (a) In the roof area of the building - On or about January 21, 2026, the employer exposed employees to a fall hazard, in that employees did not use fall protection while framing the roof of an addition to the building with an 11' fall to lower level or ground distance.
Recent events (2)
  • — I (S) $1362
  • — Z (S) $2270

1926.502 D15

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 30, 2026
Penalty
Initial $0 · Current $0
29 CFR 1926.502(d)(15): Anchorage used for attachment for personal fall arrest equipment was not capable of supporting at least 5,000 pounds (22.2 kN) per employee attached nor was it designed, installed and used as follows: As part of a complete personal fall arrest system which maintains a safety factor of at least two; and under the supervision of a qualified person.  (a) In the roof area of the building - On or about January 21, 2026, the employer exposed employees to a fall hazard, in that employees wrapped lifelines around roof framing in lieu of installing an anchorage designed to support at least 5,000 pounds.