TUCSON, AZ —
OSHA Inspection: CASINO DEL SOL RESORT
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CASINO DEL SOL RESORT in 5655 WEST VALENCIA RD., TUCSON, AZ 85757 (NAICS 721120). OSHA activity number 348709270.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CASINO DEL SOL RESORT
- Site address
- 5655 WEST VALENCIA RD.
- City
- TUCSON
- State
- AZ
- ZIP
- 85757
- Mailing
- 5655 WEST VALENCIA RD., TUCSON, AZ 85757
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 721120
- Employees
- 200
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.253 B04 III
- Issued
- Feb 27, 2026
- Penalty
- Initial $7,688 · Current $4,229 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: Chiller Plant: On or about January 26th 2026, and at times prior to, the employer did not ensure that the oxygen and acetylene compressed gas cylinders were separated by a minimum distance of 20 feet, or by a noncombustible barrier at least 5 ft. high having a fire resistance rating of at least one hour. This condition potentially exposed employee(s) to fire and explosive hazards.
Recent events (2)
- — I (S) $4229
- — Z (S) $7688
1910.303 B02
- Issued
- Feb 27, 2026
- Penalty
- Initial $6,149 · Current $3,382 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling. On or about January 26th, 2026, and at times prior thereto, a space heater and a large commercial refrigerator were not plugged in directly to a wall receptacle which was not used according to the listing and labeling instructions. This condition potentially exposed employee(s) to electrical and/or fire hazard(s). In the following location(s): a) Banquet Warehouse - black space heater plugged into an extension cord. b) Street Scape Kitchen - a large commercial refrigerator was plugged into an RPT.
Recent events (2)
- — I (S) $3382
- — Z (S) $6149
1910.305 A02 X
- Issued
- Feb 27, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(a)(2)(x): Flexible cords and cables shall be protected from accidental damage, as might be caused, for example, by sharp corners, projections, and doorways or other pinch points. Laundry : On or about January 26th, 2026, and at times prior thereto, a flexible cord was laying though the metal bathroom doorway. This condition potentially exposed employee(s) to shock hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Casino DEL SOL Resort
View Casino DEL SOL Resort's full OSHA safety record →
More inspections in this industry (NAICS 721120)
More inspections in AZ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348709270.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.