Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: D CRANE RENTAL LLC

Unprogrammed Emphasis inspection · Safety discipline

On , OSHA opened an unprogrammed Emphasis safety inspection of D CRANE RENTAL LLC in 5228 BARDES RD, MASON, OH 45040 (NAICS 236220). OSHA activity number 348712951.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D Crane Rental LLC for free Get an email when a new federal OSHA severe-injury report for D Crane Rental LLC is published. One employer, no account, unsubscribe in one click.
Establishment
D CRANE RENTAL LLC
Site address
5228 BARDES RD
City
MASON
State
OH
ZIP
45040
Mailing
57 CUMMINGS DRIVE, WALTON, KY 41094
Inspection type
Unprogrammed Emphasis (N)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Last modified
Data loaded
NAICS code
236220
Employees
1
Ownership type
Private (A)

3 citations on file for this inspection.

1926.1412 D01

Other-than-serious Gravity 10 1 instance 1 exposed
Issued
May 28, 2026
Abate by
Sep 4, 2026
Penalty
Initial $11,585 · Current $8,500 Reduced
29 CFR  1926.1412(d)(1): A competent person must begin a visual inspection prior to each shift the equipment will be used, which must be completed before or during that shift. The inspection must consist of observation for apparent deficiencies. Taking apart equipment components and booming down is not required as part of this inspection unless the results of the visual inspection or trial operation indicate that further investigation necessitating taking apart equipment components or booming down is needed. Determinations made in conducting the inspection must be reassessed in light of observations made during operation. At a minimum the inspection must include all of the following:    a.) On or about January 15, 2026, at the west side of the newly constructed hotel, the employer did not ensure that a competent person performed the required visual inspection of the crane and surrounding area prior to the shift. As a result, the operator did not verify the crane's actual distance from power lines, exposing employees to electrocution hazards. Additionally, outrigger barricades were not installed on all sides of the crane, exposing employees to struck by and crushed by hazards.
Recent events (3)
  • · F (O) $8500
  • · C (S) $11585
  • · Z (S) $11585

1926.1412 E01

Deleted Other-than-serious 1 instance 1 exposed
Issued
May 28, 2026
Abate by
Jul 2, 2026
Penalty
Initial $0 · Current $0
29 CFR  1926.1412(e)(1): Each month the equipment is in service it must be inspected in accordance with paragraph (d) of this section (each shift).     a.) On or about January 15, 2026, located at the newly constructed hotel's west side of the building the employer failed to ensure that a competent person conducted a monthly visual inspection of the crane exposing employees to possible struck-by, and crushed-by crane malfunction hazards.
Recent events (3)
  • · F (O) $0
  • · C (O) $0
  • · Z (O) $0

1926.1408 A02

Deleted Other-than-serious 1 instance 2 exposed
Issued
May 28, 2026
Abate by
Jul 2, 2026
Penalty
Initial $930 · Current $0 Reduced
29 CFR  1926.1408(a)(2): Determine if any part of the equipment, load line or load (including rigging and lifting accessories), if operated up to the equipment's maximum working radius in the work zone, could get closer than 20 feet to a power line. If so, the employer must meet the requirements in Option (1), Option (2), or Option (3) of this section, as follows:      a.) On or about January 15, 2026, at the west side of the newly constructed hotel, where the hydraulic telescoping crane, operated up to its maximum working radius, could get closer than 20 feet to the power line, the employer failed to implement the requirements of Option (1), (2), or (3), exposing employees to electrocution hazards.
Recent events (3)
  • · F (O) $0
  • · C (O) $930
  • · Z (O) $930

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348712951.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.