DAWSONVILLE, GA —
OSHA Inspection: SALGADO NIC CONTRACTOR LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of SALGADO NIC CONTRACTOR LLC in 50 ROCKAWAY DR SOUTH, DAWSONVILLE, GA 30534 (NAICS 238160). OSHA activity number 348727579.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- SALGADO NIC CONTRACTOR LLC
- Site address
- 50 ROCKAWAY DR SOUTH
- City
- DAWSONVILLE
- State
- GA
- ZIP
- 30534
- Mailing
- 4158 JONESBORO ROAD, FOREST PARK, GA 30297
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 3
- Ownership type
- A
Citations
4 citations on file for this inspection.
1926.501 B13
- Issued
- Feb 20, 2026
- Penalty
- Initial $2,270 · Current $2,270
General-duty citation text
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501(b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502: a) New residential construction located at 50 Rockaway Drive South, Dawsonville, GA 30534, Roof: On or about 02/05/2026, the employer exposed employees to fall hazards of approximately 10-feet, 2-inches to the lower level, in that a fall protection system was not provided to employees engaged in roofing activities on a 3/12 pitched roof.
Recent events (1)
- — Z (S) $2270
1926.1053 B01
- Issued
- Feb 20, 2026
- Penalty
- Initial $2,270 · Current $2,270
General-duty citation text
29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) New residential construction Located at 50 Rockaway Drive South, Dawsonville, GA 30534, Roof: On or about 02/05/2026, the employer exposed employees to fall hazards at approximately 9 feet, 10 inches to the lower ground level, in that the ladder used to access the lower roof of the structure was not extended at least 3 feet above the upper landing surface.
Recent events (1)
- — Z (S) $2270
1926.1053 B16
- Issued
- Feb 20, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired. a) New residential construction Located at 50 Rockaway Drive South, Dawsonville, GA 30534, Roof: On or about 02/05/2026, the employer exposed employees to fall hazards at approximately 9 feet, 10 inches to the lower ground level, in that the ladder used to access the lower roof of the structure had bent and damaged side rails and was not removed from service.
Recent events (1)
- — Z (S) $0
1926.552 A04
- Issued
- Feb 20, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.552(a)(4): Hoisting ropes were not installed in accordance with the wire rope manufacturers' recommendations. a) New residential construction located at 50 Rockaway Dr south, Dawsonville, GA 30534: On or about 02/05/2026, the employer did not ensure that the TranSporter Platform Hoist was equipped and maintained in compliance with the manufacturer's specifications, including proper installation of the original wire cable as designed.
Recent events (1)