BRISTOL, RI —
OSHA Inspection: CLEAR CARBON & COMPONENTS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CLEAR CARBON & COMPONENTS, INC. in 108 TUPELO STREET, BRISTOL, RI 02809 (NAICS 326199). OSHA activity number 348732702.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CLEAR CARBON & COMPONENTS, INC.
- Site address
- 108 TUPELO STREET
- City
- BRISTOL
- State
- RI
- ZIP
- 02809
- Mailing
- 108 TUPELO STREET, BRISTOL, RI 02809
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326199
- Employees
- 20
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.178 L01 I
- Issued
- Apr 6, 2026
- Penalty
- Initial $3,547 · Current $1,774 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). a) Worksite: On or about February 9, 2026, employees were exposed to struck-by and crushing hazards while working near an operator of a Nissan Powered Industrial Truck, Model CRGH02F30V that did not undergo the necessary training.
Recent events (2)
- — I (S) $1773.5
- — Z (S) $3547
1910.134 F02
- Issued
- Apr 6, 2026
- Penalty
- Initial $339 · Current $170 Reduced
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using a tight-fitting facepiece respirator were not annually fit tested. a) Worksite: On or about February 9, 2026, employees were exposed to health hazards while using tight-fitting respirators without an annual fit test as required.
Recent events (2)
- — I (O) $169.5
- — Z (O) $339
1910.147 C07 I B
- Issued
- Apr 6, 2026
- Penalty
- Initial $339 · Current $170 Reduced
General-duty citation text
29 CFR 1910.147(c)(7)(i)(B): Affected employees were not instructed in the purpose and use of the energy control procedure. a) Worksite: On or about February 9, 2026, the employer did not ensure that each affected employee was trained and instructed in the energy control procedure.
Recent events (2)
- — I (O) $169.5
- — Z (O) $339
1910.303 B02
- Issued
- Apr 6, 2026
- Penalty
- Initial $398 · Current $199 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling. a) Shipping and Receiving Area: On or about February 9, 2026, employees were exposed to electrical hazards while using a quad receptacle without the proper enclosure installed. b) Carpentry Area: On or about February 9, 2026, employees were exposed to electrical hazards while using a quad receptacle without the proper enclosure installed.
Recent events (2)
- — I (O) $199
- — Z (O) $398
1910.305 G01 IV A
- Issued
- Apr 6, 2026
- Penalty
- Initial $398 · Current $199 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. a) Paint Prep Area: On or about February 9, 2026, employees were exposed to electrical hazards while using an extension cord without GFCI protection to provide power to a Fein Turbo II HEPA Pro Set Vacuum. b) Loading Dock Area: On or about February 9, 2026, employees were exposed to electrical hazards while using an extension cord without GFCI protection to provide power to the loading dock door sensor.
Recent events (2)
- — I (O) $199
- — Z (O) $398
1910.305 G01 IV D
- Issued
- Apr 6, 2026
- Penalty
- Initial $398 · Current $199 Reduced
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were attached to building surfaces. a) Loading Dock: On or about February 9, 2026, employees were exposed to electrical hazards while using an extension cord without GFCI protection to provide power to the loading dock door sensor that was attached to the building surface.
Recent events (2)
- — I (O) $199
- — Z (O) $398