Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: STERMAN MASSER, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of STERMAN MASSER, INC. in 2 FEARNOT ROAD, SACRAMENTO, PA 17968 (NAICS 111211). OSHA activity number 348744558.

Watch Sterman Masser, INC. — free Get an email when a new federal OSHA severe-injury report for Sterman Masser, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2 FEARNOT ROAD
City
SACRAMENTO
State
PA
ZIP
17968
Mailing
P.O. BOX 210, SACRAMENTO, PA 17968
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
111211
Employees
250
Ownership type
A

6 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $13240.00 · Current $13240.00
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  a) SMI Pack Shop, Line 5 Baler: On or about February 9, 2026, employees operating machinery were exposed to amputation hazards when rethreading the needle due to the employers lockout tagout program and procedures not being utilized.  Abatement certification and documentation required.
Recent events (1)
  • — Z (S) $13240

1910.147 D02

Serious Gravity 10 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(2): The machine or equipment was not turned off or shut down using the procedures established for the machine or equipment:  a) SMI Pack Shop, Line 5 Baler: On or about February 9, 2026, employees operating machinery were exposed to amputation hazards when rethreading the needle due the machinery not being turned off using the established lockout tagout procedures for the machine.  Abatement certification and documentation required.
Recent events (1)
  • — Z (S) $0

1910.147 D03

Serious Gravity 10 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  a) SMI Pack Shop, Line 5 Baler: On or about February 9, 2026, employees operating machinery were exposed to amputation hazards when rethreading the needle due to the energy isolation devices not being utilized.  Abatement certification and documentation required.
Recent events (1)
  • — Z (S) $0

1910.147 D04 II

Serious Gravity 10 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(4)(ii): Lockout devices utilized were not affixed in a manner that held the energy isolating device in a safe or off position:  a) SMI Pack Shop, Line 5 Baler: On or about February 9, 2026, employees operating machinery were exposed to amputation hazards when rethreading the needle due to lockout devices not being used.   Abatement certification and documentation required.
Recent events (1)
  • — Z (S) $0

1910.147 D06

Serious Gravity 10 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished:  a) SMI Pack Shop, Line 5 Baler: On or about February 9, 2026, employees operating machinery were exposed to amputation hazards when rethreading the needle due to the employees not verifying the energy source were deenergized prior to performing the task.   Abatement certification and documentation required.
Recent events (1)
  • — Z (S) $0

1910.212 A03 II

Serious Gravity 10 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $13240.00 · Current $13240.00
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):  a) SMI Pack Shop, Line 5 Baler: On or about February 9, 2026, employees operating machinery were exposed to amputation hazards when operating the machine and rethreading the needle due to the lack any type of guarding over the needle.  Abetment certification and documentation.
Recent events (1)
  • — Z (S) $13240

View STERMAN MASSER, INC.'s full OSHA safety record →