FORT WORTH, TX ·
OSHA Inspection: TAPE INNOVATIONS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of TAPE INNOVATIONS LLC in 201 EAST RISINGER ROAD, FORT WORTH, TX 76140 (NAICS 326299). OSHA activity number 348744715.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- TAPE INNOVATIONS LLC
- Site address
- 201 EAST RISINGER ROAD
- City
- FORT WORTH
- State
- TX
- ZIP
- 76140
- Mailing
- 201 EAST RISINGER ROAD, FORT WORTH, TX 76140
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 326299
- Employees
- 53
- Ownership type
- Private (A)
Citations
5 citations on file for this inspection.
1910.133 A01
- Issued
- Jun 9, 2026
- Penalty
- Initial $6,753 · Current $4,052 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation: On or about March 12, 2026, the employer did not ensure employees working in the Production area of the facility applying spray adhesive to materials were provided with the appropriate personal protective equipment to protect against flying debris and liquid chemicals (safety glasses).
Recent events (2)
- · I (S) $4051.8
- · Z (S) $6753
1910.303 B08 I
- Issued
- Jun 9, 2026
- Penalty
- Initial $4,502 · Current $2,701 Reduced
General-duty citation text
29 CFR 1910.303(b)(8)(i): Electrical equipment was not firmly secured to the surface on which it was mounted. On or about February 12, 2026, an electrical disconnect junction box for the Preco 2 machine was not securely mounted to the floor to prevent employee(s) from being exposed to potential electrical hazards while performing maintenance or cleaning duties requiring the use of the disconnect.
Recent events (2)
- · I (S) $2701.2
- · Z (S) $4502
1910.1200 E01
- Issued
- Jun 9, 2026
- Abate by
- Jul 9, 2026
- Penalty
- Initial $7,945 · Current $4,767 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: On or about February 12, 2026, the employer had not developed, maintained or implemented a written hazardous communication program at the facility.
Recent events (2)
- · I (S) $4767
- · Z (S) $7945
1910.37 B04
- Issued
- Jun 9, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.37(b)(4): Signs were not posted along the exit access indicating the direction of travel to the nearest exit and exit discharge when the direction of travel to the exit or exit discharge was not immediately apparent: On or about February 12, 2026, designated paths of egress toward and through the employee breakroom did not have exit signs indicating the direction of travel for employees to the nearest emergency exit.
Recent events (2)
- · I (O) $0
- · Z (O) $0
1910.132 D02
- Issued
- Jun 9, 2026
- Abate by
- Jul 9, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify that the required workplace hazard assessment has been performed through a written certification which included the requirements as outlined in 29 CFR 1910.132(d)(2): On or about February 12, 2026, the employer did not certify, in writing, that the workplace hazard assessment had been performed.
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 326299)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348744715.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.