OSHA Inspection: ESSEX BAY ENGINEERING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ESSEX BAY ENGINEERING, INC. in 19 MITCHELL ROAD, IPSWICH, MA 01938 (NAICS 332710). OSHA activity number 348748724.

Watch Essex BAY Engineering, INC. — free Get an email when a new federal OSHA severe-injury report for Essex BAY Engineering, INC. is published. One employer, no account, unsubscribe in one click.
Site address
19 MITCHELL ROAD
City
IPSWICH
State
MA
ZIP
01938
Mailing
19 MITCHELL ROAD, IPSWICH, MA 01938
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
332710
Employees
41
Ownership type
A

3 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 17, 2026
Abate by
May 22, 2026
Penalty
Initial $5,628 · Current $2,814 Reduced
29 CFR  1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:   (a) Location - Fabrication:  On or about 2/13/26, the point of operation on an Amada press brake was not guarded.  (b) Location - Polishing/deburring:  On or about 2/13/26, ingoing nip points on a Dynabrade versatility grinder were not guarded.
Recent events (2)
  • — I (S) $2814
  • — Z (S) $5628

1910.37 B02

Other-than-serious 1 instance 1 exposed
Issued
Mar 17, 2026
Abate by
May 1, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.37(b)(2):  Each exit was not clearly visible and marked by a sign reading "Exit":  Location - Building 3:  On or about 2/13/26, an exit was not clearly marked by a sign reading "EXIT."
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.37 B05

Other-than-serious 2 instances 1 exposed
Issued
Mar 17, 2026
Abate by
May 1, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.37(b)(5):  Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use (e.g. closet):  Location - Building 3:  On or about 2/13/26, there were two doorway passages leading to other tenant spaces in the building that were not marked "NOT AN EXIT."