Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: INLAND FLEXO, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of INLAND FLEXO, LLC in 2442 PROGRESS CT., NEENAH, WI 54956 (NAICS 323111). OSHA activity number 348752593.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Inland Flexo, LLC — free Get an email when a new federal OSHA severe-injury report for Inland Flexo, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
INLAND FLEXO, LLC
Site address
2442 PROGRESS CT.
City
NEENAH
State
WI
ZIP
54956
Mailing
2442 PROGRESS COURT, NEENAH, WI 54956
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323111
Employees
34
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
May 1, 2026
Abate by
Jun 1, 2026
Penalty
Initial $11,254 · Current $5,000 Reduced
OSH ACT of 1970 Section (5)(a)(1):  The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees.  On or about February 11, 2026, at an establishment located at 242 Progress Court, Neenah, Wisconsin, in the Finishing Department, employees conducting roll changes on the turret/rewind side of the K4 Karlville Beyond Converting, Machine Name:  Seaming Machine for Shrink Labels, were exposed to entanglement and caught in hazards and the employer failed to train employees on the hazards created by the turret.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $11254

1910.303 B02

Deleted Other-than-serious 2 instances 3 exposed
Issued
May 1, 2026
Abate by
Jun 1, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2):  Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.  (a)  On or about February 18, 2026 , at an establishment located at 242 Progress Court, Neenah, Wisconsin, in the Finishing Department, on the K4Seamer at the turret rewind portion of the machine was a quad metallic outlet box which was suspended as a drop pendant and used to power various accessories such as an de-ionizer and a scale.  The metal outlet box was not installed in accordance with the UL identifier QCIT, which states that boxes shall be mounted in or on a surface exposing employees to electrical shock hazards.  (b)  On or about February 18, 2026 , at an establishment located at 242 Progress Court, Neenah, Wisconsin, in the Finishing Department, on the rewinder next to the K4 Seamer was another quad metallic outlet box which was suspended as a drop pendant and placed on top of the electrical cabinet.  An orange extension cord was plugged into the outlet to provide temporary power to a black light used on the K4 Seamer as well as two additional plugs for different pieces of equipment.  The metal outlet box was not installed in accordance with the UL identifier QCIT, which states that boxes shall be mounted in or on a surface exposing employees to electrical shock hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348752593.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.