OSHA Inspection: RIVERA ROOFING

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of RIVERA ROOFING in 2000 NORTH HIGHWAY 20, WATERTOWN, SD 57201 (NAICS 321992). OSHA activity number 348753674.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Rivera Roofing — free Get an email when a new federal OSHA severe-injury report for Rivera Roofing is published. One employer, no account, unsubscribe in one click.
Establishment
RIVERA ROOFING
Site address
2000 NORTH HIGHWAY 20
City
WATERTOWN
State
SD
ZIP
57201
Mailing
145 2ND AVENUE SOUTH, BROOKINGS, SD 57006
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
321992
Employees
5
Ownership type
A

4 citations on file for this inspection.

1910.23 C11

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 7, 2026
Penalty
Initial $2,412 · Current $2,412
29 CFR 1910.23(c)(11): The employer did not ensure that portable ladders used to gain access to an upper landing surface that have side rails that extend at least 3 feet (0.9 m) above the upper landing surface:  (a)Rivera Roofing at 2000 North Highway 20, Watertown, SD 57201: On or about and at times prior to February 17, 2026, the employer did not ensure that the Werner 32-foot Aluminum extension ladder, Model Number: DI332-2, Part Number: 113526-05 that the employees were using was extended at least three feet above the upper landing surface of the roof of a prefabricated wood building.  This condition exposed employees to fall hazards greater than four feet.
Recent events (1)
  • — Z (S) $2412

1910.28 B01 I

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 7, 2026
Abate by
May 7, 2026
Penalty
Initial $3,972 · Current $3,972
29 CFR  1910.28(b)(1)(i): Except as provided elsewhere in this section 29 CFR 1910.28, the employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2 m) or more above a lower level is protected from falling by one or more of the systems described in 29 CFR 1910.28(b)(1)(i):  (a)Rivera Roofing at 2000 North Highway 20, Watertown, SD 57201: On or about and at times prior to February 17, 2026, the employer did not ensure that employees were protected from falls while conducting roofing operations on a prefabricated wood building. This condition exposed the employees to fall hazards greater than four feet.
Recent events (1)
  • — Z (S) $3972

1910.30 A01

Serious Gravity 10 1 instance 5 exposed
Issued
Apr 7, 2026
Abate by
May 7, 2026
Penalty
Initial $0 · Current $0
29 CFR 1910.30(a)(1): The employer did not provide training for each employee who uses personal fall protection systems or who is required to be trained as specified elsewhere in this subpart before any employee is exposed to a fall hazard, and/or the employer did not ensure employees are trained in the requirements of this paragraph on or before May 17, 2017:  (a)Rivera Roofing at 2000 North Highway 20, Watertown, SD 57201: On or about and at times prior to February 17, 2026, the employer did not ensure that employees were properly trained on the use of fall protection systems prior to being exposed to the fall hazards while working on a prefabricated wood building roof.  This condition exposed employees to fall hazards greater than four feet.
Recent events (1)
  • — Z (S) $0

1910.133 A01

Serious Gravity 1 1 instance 5 exposed
Issued
Apr 7, 2026
Abate by
May 7, 2026
Penalty
Initial $1,702 · Current $1,702
29 CFR  1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  (a)Rivera Roofing at 2000 North Highway 20, Watertown, SD 57201: On or about and at times prior to February 17, 2026, the employer did not ensure that each employee that was installing roof shingles on a prefabricated wood building with the use of a pneumatic nail gun were protected from flying particles by the use of appropriate eye protection.  This condition exposed employees to struck-by hazards.
Recent events (1)
  • — Z (S) $1702