Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: SUMMIT TRAILERS, LLC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SUMMIT TRAILERS, LLC. in 2174 FAIR ROAD, SCHUYLKILL HAVEN, PA 17972 (NAICS 336212). OSHA activity number 348761859.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Summit Trailers, LLC. for free Get an email when a new federal OSHA severe-injury report for Summit Trailers, LLC. is published. One employer, no account, unsubscribe in one click.
Site address
2174 FAIR ROAD
City
SCHUYLKILL HAVEN
State
PA
ZIP
17972
Mailing
2174 FAIR ROAD, SCHUYLKILL HAVEN, PA 17972
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Union (A)
Opened
Closing conference
Last modified
Data loaded
NAICS code
336212
Employees
27
Ownership type
Private (A)

10 citations on file for this inspection.

1910.184 E04

Serious Gravity 10 1 instance 2 exposed
Issued
Jul 8, 2026
Abate by
Jul 20, 2026
Penalty
Initial $9,268 · Current $5,564 Reduced
1910.184(e)(4)  Certificate(s) of proof test were not available for new, repaired or reconditioned alloy steel chain slings:  a) Building 1 - South Crane: On or about February 12, 2026: Employees operating a single?girder underhung crane were exposed to serious injury while lifting and moving steel plates through the use of a homemade, unrated, and unmarked below?the?hook lifting device. The device lacked engineering approval, load rating, and identification, creating a recognized hazard of dropped loads and catastrophic equipment failure.  Abatement certification and documentation required.
Recent events (2)
  • · I (S) $5564
  • · Z (S) $9268

5(a)(1)

Serious Gravity 10 2 instances 20 exposed
Issued
Jul 8, 2026
Abate by
Jul 27, 2026
Penalty
Initial $9,268 · Current $5,564 Reduced
1910.184(e)(4)  a) Building 1: On or about February 12, 2026: Employees operating single?girder underhung cranes were exposed to serious injury while moving structural steel beams. The cranes and the facility lacked any directional travel markings, creating a recognized hazard of crane misoperation.  b) Building 2: On or about February 12, 2026: Employees operating single?girder underhung cranes were exposed to serious injury while moving structural steel beams due to the absence of directional markings on the crane equipment and within the facility, creating a recognized hazard.  Abatement certification and documentation required.
Recent events (2)
  • · I (S) $5564
  • · Z (S) $9268

1910.36 E02

Serious Gravity 5 2 instances 1 exposed
Issued
Jul 8, 2026
Abate by
Aug 10, 2026
Penalty
Initial $5,296 · Current $3,165 Reduced
29 CFR  1910.36(e)(2): A door that connects any room to an exit route did not swing out in the direction of exit travel when the room was a high hazard area (i.e., contains contents that are likely to burn with extreme rapidity or explode):  a) Paint Spray Room: On or about February 19, 2026, employees spraying flammable paints were exposed to fire hazards because the exit door between the paint spray booth and the wash/prep bay opened inward toward the paint spray room instead of swinging in the direction of exit travel.  b) Flammables Storage Room: On or about February 19, 2026, employees storing and mixing flammable paints were exposed to fire hazards because the door to the flammables storage room opened inward into the room rather than in the direction of exit travel.  Abatement certification required.
Recent events (2)
  • · I (S) $3165
  • · Z (S) $5296

1910.37 A02

Serious Gravity 5 2 instances 27 exposed
Issued
Jul 8, 2026
Abate by
Aug 3, 2026
Penalty
Initial $5,296 · Current $3,165 Reduced
29 CFR 1910.37(a)(2): Exit routes were not arranged so that employees did not have to travel toward a high hazard area:  a) Floor Bay, Building 1: On or about February 19, 2026, employees working in Building 1 were exposed to fire hazards due to full acetylene and propane tanks being stored directly outside of door "Zone C," requiring employees to travel toward a high?hazard area when using this exit route.  b) Paint Room, Building 2: On or about February 19, 2026, employees working in the paint room were exposed to fire hazards due to waste flammable liquid paint being stored directly outside of the rear fire exit door, requiring employees to travel toward a high?hazard area when using this exit route.  Abatement certification required.
Recent events (2)
  • · I (S) $3165
  • · Z (S) $5296

1910.106 D04 I

Serious Gravity 5 1 instance 5 exposed
Issued
Jul 8, 2026
Abate by
Aug 10, 2026
Penalty
Initial $5,296 · Current $3,165 Reduced
29 CFR  1910.106(d)(4)(i): Inside flammable or combustible liquid storage room(s) were not constructed to meet the required fire-resistive rating as specified in NFPA 251-1969:  a) Flammable Storage Room: On or about February 19, 2026, employees working in the flammables storage room were exposed to fire hazards due to a grated opening in the fire?rated wall that did not contain any type of firestop system.   Abatement certification required.
Recent events (2)
  • · I (S) $3165
  • · Z (S) $5296

1910.212 A01

Serious Gravity 1 1 instance 1 exposed
Issued
Jul 8, 2026
Abate by
Aug 3, 2026
Penalty
Initial $3,972 · Current $2,387 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  a) Machine Shop, Building 1: On or about February 19, 2026, employees were exposed to rotating parts and flying particles while operating the Walker Turner drill press due to the lack of any appropriate guard to protect the operator.  Abatement certification required.
Recent events (2)
  • · I (S) $2387
  • · Z (S) $3972

1910.212 A03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jul 8, 2026
Abate by
Aug 3, 2026
Penalty
Initial $6,621 · Current $3,976 Reduced
29 CFR  1910.212(a)(3)(ii): The  point of operation of machines whose operation exposed an employee to injury, was not guarded:  a) Floor Bay, Building 1: On or about February 19, 2026, employees were exposed to amputation hazards while using a punch press due to the manufacturers front guard being removed.   Abatement certification required.
Recent events (2)
  • · I (S) $3976
  • · Z (S) $6621

1910.252 B02 III

Serious Gravity 1 2 instances 20 exposed
Issued
Jul 8, 2026
Abate by
Jul 27, 2026
Penalty
Initial $3,972 · Current $2,388 Reduced
29 CFR 1910.252(b)(2)(iii):  Workers and other persons adjacent to welding areas were not protected from welding rays by noncombustible or flameproof screens or shields:  a) Building 1 Shop: On or about February 12, 2026, employees were exposed to welding rays generated by resistance welding operations without welding screens or shields.  b) Building 2 Shop: On or about February 12, 2026, employees were exposed to welding rays generated by resistance welding operations without welding screens or shields.  Abatement certification required.
Recent events (2)
  • · I (S) $2388
  • · Z (S) $3972

1910.303 G01 I

Serious Gravity 1 1 instance 15 exposed
Issued
Jul 8, 2026
Abate by
Aug 10, 2026
Penalty
Initial $3,972 · Current $2,388 Reduced
29 CFR 1910.303(g)(1)(i): The dimension of the working space in the direction of access to live parts operating at 600 volts or less, and likely to require examination, adjustment, servicing, or maintenance while energized, was less than required by Table S?1:  a) Bucket Area, Building 1: On or about February 12, 2026, employees were exposed to electrical hazards due to containers and equipment being placed in front of electrical panels supplying less than 600 volts.   Abatement certification required.
Recent events (2)
  • · I (S) $2388
  • · Z (S) $3972

1910.305 G01 IV B

Serious Gravity 1 2 instances 5 exposed
Issued
Jul 8, 2026
Abate by
Jul 20, 2026
Penalty
Initial $3,972 · Current $2,388 Reduced
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors:  a) Paint Spray Booth: On or about February 19, 2026, employees were exposed to shock hazards while working in the paint spray booth due to a powered flexible cord being run through a hole in the steel side wall.   b) Flammables Storage Room: On or about February 19, 2026, employees were exposed to shock hazards while working in the flammables storage room due to the power cord of the paint mixer being run through an expanded metal grate in the wall.  Abatement certification required.
Recent events (2)
  • · I (S) $2388
  • · Z (S) $3972

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348761859.