CONROE, TX —
OSHA Inspection: HEMPEL (USA), INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of HEMPEL (USA), INC. in 600 CONROE PARK NORTH DR., CONROE, TX 77303 (NAICS 325510). OSHA activity number 348773888.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- HEMPEL (USA), INC.
- Site address
- 600 CONROE PARK NORTH DR.
- City
- CONROE
- State
- TX
- ZIP
- 77303
- Mailing
- 600 CONROE PARK NORTH DR., CONROE, TX 77303
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325510
- Employees
- 151
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 I
- Issued
- Apr 16, 2026
- Abate by
- May 12, 2026
- Penalty
- Initial $11,254 · Current $11,254
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: On or about February 24, 2026, an employee was performing service and /or maintenance on a solvent recovery unit without energy control procedures being documented or utilized.
Recent events (2)
- — I (O) $11254
- — Z (S) $11254
1910.147 D03
- Issued
- Apr 16, 2026
- Abate by
- May 12, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s): On or about February 24, 2026, an employee was performing service and /or maintenance on a solvent recovery unit without isolating the power to the machine.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.147 D04 I
- Issued
- Apr 16, 2026
- Abate by
- May 12, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: On or about February 24, 2026, an employee was performing service and /or maintenance on a solvent recovery unit without locking out the machine.
Recent events (2)
- — I (O) $0
- — Z (S) $0
More inspections at Hempel (USA), INC.
View Hempel (USA), INC.'s full OSHA safety record →
More inspections in this industry (NAICS 325510)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348773888.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.