OSHA Inspection: CADCOM INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of CADCOM INC in 110 RATON DRIVE, MILFORD, CT 06461 (NAICS 332721). OSHA activity number 348778192.

Watch Cadcom INC — free Get an email when a new federal OSHA severe-injury report for Cadcom INC is published. One employer, no account, unsubscribe in one click.
Establishment
CADCOM INC
Site address
110 RATON DRIVE
City
MILFORD
State
CT
ZIP
06461
Mailing
110 RATON DRIVE, MILFORD, CT 06461
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
332721
Employees
13
Ownership type
A

3 citations on file for this inspection.

1910.147 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $1929.00 · Current $1350.00 Reduced
29 CFR  1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  WORKSHOP/110 RATON DRIVE, MILFORD, CT, 06461:  On/or about March 2, 2026, and times prior to, the employer did not establish a hazardous energy control lockout/tagout program for the employees on the machinery such as but not limited to the CNC lathes and mills.  ABATED DURING THE INSPECTION
Recent events (2)
  • — I (S) $1350.3
  • — Z (S) $1929

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  WORKSHOP/110 RATON DRIVE, MILFORD, CT, 06461:  On/or about March 2, 2026, and times prior to, the employer did not establish hazardous energy control lockout/tagout energy control procedures for the employees on the machinery such as but not limited to the CNC lathes and mills.  ABATED DURING THE INSPECTION
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Penalty
Initial $1929.00 · Current $1350.00 Reduced
29 CFR  1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  WORKSHOP/110 RATON DRIVE, MILFORD, CT, 06461: On/or about March 2, 2026, and times prior to, the employer did not ensure the rotating collets on the Hardinge lathes were guarded.  ABATED DURING THE INSPECTION.
Recent events (2)
  • — I (S) $1350.3
  • — Z (S) $1929

View CADCOM INC's full OSHA safety record →