ORCHARD PARK, NY ·
OSHA Inspection: STI-CO ANTENNA SOLUTIONS
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of STI-CO ANTENNA SOLUTIONS in 15 COBHAM DRIVE, ORCHARD PARK, NY 14127 (NAICS 334220). OSHA activity number 348794579.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- STI-CO ANTENNA SOLUTIONS
- Site address
- 15 COBHAM DRIVE
- City
- ORCHARD PARK
- State
- NY
- ZIP
- 14127
- Mailing
- 15 COBHAM DRIVE, ORCHARD PARK, NY 14127
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 334220
- Employees
- 52
- Ownership type
- Private (A)
Citations
3 citations on file for this inspection.
1910.1025 D02
- Issued
- May 27, 2026
- Abate by
- Jun 29, 2026
- Penalty
- Initial $6,809 · Current $6,809
1591
General-duty citation text
29 CFR 1910.1025(d)(2): An initial determination was not made to determine if any employee may be exposed to lead at or above the action level: a) Rail cell: On or about 03/09/2026, an initial determination was not made to determine if employees would be exposed to lead above the action level for employees soldering with flux core solder containing lead. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $6809
- · Z (S) $6809
1910.1025 L01 I
- Issued
- May 27, 2026
- Abate by
- Jun 29, 2026
- Penalty
- Initial $6,809 · Current $0 Reduced
1591
General-duty citation text
29 CFR 1910.1025(l)(1)(i): Employee(s) working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025: a) Rail cell: On or about 03/09/2026, employees exposed to lead while soldering with flux core solder containing lead, were not informed of the content of Appendices A and B of 29 CFR 1910.1025. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $6809
1910.1025 M01 III
- Issued
- May 27, 2026
- Abate by
- Jun 29, 2026
- Penalty
- Initial $0 · Current $0
1591
General-duty citation text
29 CFR 1910.1025(m)(1)(iii): The employer did not include lead in the hazard communication program established to comply with the hazard communication standard (1910.1200). a) Rail cell: On or about 03/09/2026, lead was not included in the hazard communication program established to comply with the hazard communication standard (1910.1200), for employees soldering with flux core solder containing lead. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- · I (S) $0
- · Z (S) $0
More inspections in this industry (NAICS 334220)
More inspections in NY
Source