Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R&R GENERAL CONSTRUCTION INCORPORATED

Discrimination inspection · Safety discipline

On , OSHA opened a discrimination safety inspection of R&R GENERAL CONSTRUCTION INCORPORATED in 17W771 KIRKLAND, VILLA PARK, IL 60181 (NAICS 238160). OSHA activity number 348803826.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R&R General Construction Incorporated — free Get an email when a new federal OSHA severe-injury report for R&R General Construction Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
17W771 KIRKLAND
City
VILLA PARK
State
IL
ZIP
60181
Mailing
152 SPRINGLEAF, BOLINGBROOK, IL 60440
Inspection type
Discrimination (N)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Apr 24, 2026
Abate by
May 8, 2026
Penalty
Initial $3,972 · Current $2,220 Reduced
29 CFR  1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  On or about March 12, 2026 employees performing residential roofing operations were utilizing fall protection, exposing employees to an 18 foot fall.   Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $2220
  • — Z (S) $3972

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Apr 24, 2026
Abate by
May 8, 2026
Penalty
Initial $2,838 · Current $1,580 Reduced
29 CFR  1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  On or about March 12, 2026 employees used an extension ladder that did not extend three feet past the roof they accessed, exposing employees to an 18 foot fall.   Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $1580
  • — Z (S) $2838

1926.503 B01

Other-than-serious 1 instance 4 exposed
Issued
Apr 24, 2026
Abate by
May 8, 2026
Penalty
Initial $0 · Current $0
29 CFR  1926.503(b)(1): The employer shall verify compliance with paragraph (a) of this section by preparing a written certification record. The written certification record shall contain the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer. If the employer relies on training conducted by another employer or completed prior to the effective date of this section, the certification record shall indicate the date the employer determined the prior training was adequate rather than the date of actual training.  On or about March 12, 2026 the employer did not certify fall training for employees performing residential roofing operations at heights exceeding six feet.  Abatement documentation is required of this item in accordance with the requirements of 29 CFR 1903.19(d).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348803826.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.