Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,197,549Inspections Most recent open 2026-08-27 Last loaded 2026-08-31

OSHA Inspection: PATCO MACHINE & FAB., INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of PATCO MACHINE & FAB., INC. in 2002 HUMBLE WESTFIELD ROAD, HOUSTON, TX 77073 (NAICS 332710). OSHA activity number 348814658.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Patco Machine & FAB., INC. for free Get an email when a new federal OSHA severe-injury report for Patco Machine & FAB., INC. is published. One employer, no account, unsubscribe in one click.
Site address
2002 HUMBLE WESTFIELD ROAD
City
HOUSTON
State
TX
ZIP
77073
Mailing
2002 HUMBLE WESTFIELD ROAD, HOUSTON, TX 77073
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
24
Ownership type
Private (A)

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 5 1 instance 2 exposed
Issued
May 7, 2026
Abate by
Jun 3, 2026
Penalty
Initial $2,412 · Current $1,447 Reduced
29 CFR  1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:  On or about March 18, 2026, an employee replaced a blade on a saw without utilizing energy control procedures.
Recent events (2)
  • · I (S) $1447.2
  • · Z (S) $2412

1910.147 D03

Serious Gravity 5 1 instance 2 exposed
Issued
May 7, 2026
Abate by
Jun 3, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  On or about March 18, 2026, an employee replaced a blade on a saw without isolating the energy source.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.147 D04 I

Serious Gravity 5 1 instance 2 exposed
Issued
May 7, 2026
Abate by
Jun 3, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  On or about March 18, 2026, an employee replaced a blade on a saw without affixing a lockout device to the energy isolating device.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 348814658.