Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: THE GAS GUYS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of THE GAS GUYS, LLC in 2823 N ORANGE BLOSSOM TRAIL, ORLANDO, FL 32804 (NAICS 238220). OSHA activity number 348818519.

Watch THE GAS Guys, LLC — free Get an email when a new federal OSHA severe-injury report for THE GAS Guys, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
THE GAS GUYS, LLC
Site address
2823 N ORANGE BLOSSOM TRAIL
City
ORLANDO
State
FL
ZIP
32804
Mailing
2240 MARSH SEDGE LN, WINTER PARK, FL 32792
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
238220
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.651 C02

Serious Gravity 5 1 instance 5 exposed
Issued
Penalty
Initial $2838 · Current $1419 Reduced
29 CFR  1926.651(c)(2):A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  a. On or about March 19, 2026, at the jobsite: the employer allowed employees to work in an excavation without a stairway, ladder, ramp or other safe means of egress located in an excavation 14' long x 29' wide and 5'8" deep, with near vertical walls, in class c soil, exposing employees to cave-in and suffocation hazards.
Recent events (2)
  • — I (S) $1419
  • — Z (S) $2838

1926.651 I02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $3972 · Current $1986 Reduced
29 CFR  1926.651(i)(2)(i): A support system, such as underpinning, was not provided to ensure the safety of employees and the stability of the structure.  a. On or about March 19, 2026, at the jobsite: employees were exposed to fall and struck-by hazards, in that a slab of concrete of the parking lot was not supported or underpinned while employees stand and worked around it installing sewer pipe lines.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3972

1926.651 J02

Deleted Serious Gravity 10 1 instance 5 exposed
Issued
Penalty
Initial $3972 · Current $0 Reduced
29 CFR  1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.  a. On or about March 19, 2026, at the jobsite: the employer allowed employees to work in an excavation without the excavated materials at least 2 feet from the edge of an excavation 14' long x 29' wide and 5'8" deep, with near vertical walls, in class C soil, exposing employees to crushing and struck by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3972

1926.652 A01

Serious Gravity 10 1 instance 5 exposed
Issued
Penalty
Initial $3972 · Current $1986 Reduced
29 CFR  1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).  a. On or about March 19, 2026, at the jobsite: employees exposed to cave-in, suffocation and struck-by hazards, in that a cave-in protection was not installed in a 5'8" foot deep trench, with near vertical wall in type c soil, while contractors and subcontractors were installing an E1 Station and 6" SDR46 sewer pipes.
Recent events (2)
  • — I (S) $1986
  • — Z (S) $3972

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348818519.