Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: FERAZZOLI IMPORTS OF NEW ENGLAND

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of FERAZZOLI IMPORTS OF NEW ENGLAND in 103 TERRACE HALL AVE, BURLINGTON, MA 01803 (NAICS 444190). OSHA activity number 348835695.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ferazzoli Imports of NEW England — free Get an email when a new federal OSHA severe-injury report for Ferazzoli Imports of NEW England is published. One employer, no account, unsubscribe in one click.
Site address
103 TERRACE HALL AVE
City
BURLINGTON
State
MA
ZIP
01803
Mailing
103 TERRACE HALL AVENUE, BURLINGTON, MA 01803
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
444190
Employees
6
Ownership type
A

3 citations on file for this inspection.

1910.178 L06

Serious Gravity 5 1 instance 1 exposed
Issued
May 29, 2026
Abate by
Jul 6, 2026
Penalty
Initial $6,809 · Current $1,800 Reduced
29 CFR  1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):  Location: Warehouse  On or about 3/26/26, the employer did not certify that the operator of a Raymond 4460C4Q sit down powered industrial truck was evaluated and trained prior to the operator using the powered industrial truck.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $6809

1910.303 G01

Other-than-serious 1 instance 6 exposed
Issued
May 29, 2026
Penalty
Initial $956 · Current $400 Reduced
29 CFR  1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:  Location: Server closet  On or about 3/26/26, the employer did not ensure that a closet containing electrical panels was kept sufficiently clear with adequate space about the electrical equipment to ensure safe operation, and access in the event of an emergency.
Recent events (2)
  • — I (O) $400
  • — Z (O) $956

1910.303 E

Other-than-serious 1 instance 6 exposed
Issued
May 29, 2026
Abate by
Jul 6, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.303(e): Markings were not provided on electrical equipment giving voltage, current, wattage, and other ratings as necessary:   Location: Server closet  On or about 3/26/26, the employer did not ensure that electrical panels inside an interior closet was marked with the voltage provided to each electrical breaker box.