BURLINGTON, MA —
OSHA Inspection: FERAZZOLI IMPORTS OF NEW ENGLAND
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of FERAZZOLI IMPORTS OF NEW ENGLAND in 103 TERRACE HALL AVE, BURLINGTON, MA 01803 (NAICS 444190). OSHA activity number 348835695.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FERAZZOLI IMPORTS OF NEW ENGLAND
- Site address
- 103 TERRACE HALL AVE
- City
- BURLINGTON
- State
- MA
- ZIP
- 01803
- Mailing
- 103 TERRACE HALL AVENUE, BURLINGTON, MA 01803
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 444190
- Employees
- 6
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.178 L06
- Issued
- May 29, 2026
- Abate by
- Jul 6, 2026
- Penalty
- Initial $6,809 · Current $1,800 Reduced
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l): Location: Warehouse On or about 3/26/26, the employer did not certify that the operator of a Raymond 4460C4Q sit down powered industrial truck was evaluated and trained prior to the operator using the powered industrial truck.
Recent events (2)
- — I (S) $1800
- — Z (S) $6809
1910.303 G01
- Issued
- May 29, 2026
- Penalty
- Initial $956 · Current $400 Reduced
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: Location: Server closet On or about 3/26/26, the employer did not ensure that a closet containing electrical panels was kept sufficiently clear with adequate space about the electrical equipment to ensure safe operation, and access in the event of an emergency.
Recent events (2)
- — I (O) $400
- — Z (O) $956
1910.303 E
- Issued
- May 29, 2026
- Abate by
- Jul 6, 2026
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(e): Markings were not provided on electrical equipment giving voltage, current, wattage, and other ratings as necessary: Location: Server closet On or about 3/26/26, the employer did not ensure that electrical panels inside an interior closet was marked with the voltage provided to each electrical breaker box.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 444190)
More inspections in MA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348835695.