Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: LEE SPRING COMPANY LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of LEE SPRING COMPANY LLC in 1820 NEW BRITAIN AVENUE, FARMINGTON, CT 06032 (NAICS 332613). OSHA activity number 348843707.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch LEE Spring Company LLC for free Get an email when a new federal OSHA severe-injury report for LEE Spring Company LLC is published. One employer, no account, unsubscribe in one click.
Site address
1820 NEW BRITAIN AVENUE
City
FARMINGTON
State
CT
ZIP
06032
Mailing
1820 NEW BRITAIN AVENUE, FARMINGTON, CT 06032
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332613
Employees
23
Ownership type
Private (A)

6 citations on file for this inspection.

1910.29 F04

Serious Gravity 1 1 instance 12 exposed
Issued
Jun 15, 2026
Penalty
Initial $4,788 · Current $2,394 Reduced
29 CFR  1910.29(f)(4):  The employer did not ensure that no opening in a stair rail system exceeds 19 inches (48 cm) at its least dimension:  Mezzanine Access Stairs:  On, or about, April 7, 2026, a midrail was not provided on the fixed stairs that provided access to the upstairs production area.
Recent events (2)
  • · I (S) $2394
  • · Z (S) $4788

1910.217 B03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 15, 2026
Abate by
Aug 3, 2026
Penalty
Initial $7,981 · Current $3,990 Reduced
29 CFR  1910.217(b)(3)(ii): Mechanical power press(es) using a full revolution clutch and a single-stroke mechanism dependent upon spring action were not provided with spring(s) of the compression type, operating on a rod or guided within a hole or tube, and designed to prevent interleaving of the spring coils in event of breakage:  Upstairs:  On, or about, April 7, 2026, the design of the compression spring provided for the single stroke mechanism on the Perkins full revolution mechanical power press would allow interleaving of the spring in the event of breakage.
Recent events (2)
  • · I (S) $3990
  • · Z (S) $7981

1910.217 B04 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 15, 2026
Abate by
Aug 3, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.217(b)(4)(i): Pedal mechanism(s) on mechanical power press(es) full revolution clutches were not protected to prevent unintended operation from falling or moving objects or by accidental stepping onto the pedals:  Upstairs:  On, or about, April 7, 2026, the foot pedal provided on the Perkins full revolution mechanical power press was not protected against accidental contact.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.217 C02 I A

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 15, 2026
Abate by
Aug 3, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.217(c)(2)(i)(a): Point of operation guard(s) on mechanical power press(es) did not prevent entry of hands or fingers into the point of operation by reaching through, over, under or around the guard(s):  Upstairs:  On, or about, April 7, 2026, the plexiglass barrier guard provided on the Perkins full revolution mechanical power press allowed access to the point of operation by reaching over or around the press.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.217 E01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jun 15, 2026
Abate by
Aug 3, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment:  Upstairs:  On, or about, April 7, 2026, the employer had not developed and implemented a program to conduct and document periodic inspections of the Perkins full revolution mechanical power press.
Recent events (2)
  • · I (S) $0
  • · Z (S) $0

1910.303 B02

Other-than-serious 1 instance 2 exposed
Issued
Jun 15, 2026
Penalty
Initial $0 · Current $0
29 CFR  1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:  Speedwinder Department, Machine #2:  On, or about, March 30, 2026, a two wire Comfort Zone fan was used for general cooling.
Recent events (2)
  • · I (O) $0
  • · Z (O) $0

View LEE Spring Company LLC's full OSHA safety record →