GAINESVILLE, FL —
OSHA Inspection: CONTRERAS ROOFING SERVICES, LLC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CONTRERAS ROOFING SERVICES, LLC in 4601 NW 53RD AVENUE, GAINESVILLE, FL 32653 (NAICS 238160). OSHA activity number 348846411.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CONTRERAS ROOFING SERVICES, LLC
- Site address
- 4601 NW 53RD AVENUE
- City
- GAINESVILLE
- State
- FL
- ZIP
- 32653
- Mailing
- 1528 NW STATE RD 45 LOT C, NEWBERRY, FL 32669
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 8
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.501 B11
- Issued
- May 1, 2026
- Penalty
- Initial $4,965 · Current $4,965
General-duty citation text
29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a. On the roof, at a commercial building, located at 4601 NW 53rd Avenue, in Gainesville, FL: On or about March 31, 2026, the employer exposed employees to fall hazards in that fall protection was not utilized by employees while performing roofing work.
Recent events (1)
- — Z (S) $4965
1926.1053 B01
- Issued
- May 1, 2026
- Penalty
- Initial $2,837 · Current $2,837
General-duty citation text
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder: a. On the roof, at a commercial building, located at 4601 NW 53rd Avenue, in Gainesville, FL: On or about March 31, 2026, the employer exposed employees to fall hazards, in that the ladder rails did not extend 3-foot above the upper landing surface of the roof at the eave.
Recent events (1)
- — Z (S) $2837
More inspections in this industry (NAICS 238160)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348846411.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.