Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DCL BUILDERS INC.

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of DCL BUILDERS INC. in 112 FRONT STREET, EXETER, NH 03833 (NAICS 236116). OSHA activity number 348861238.

Watch DCL Builders INC. — free Get an email when a new federal OSHA severe-injury report for DCL Builders INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DCL BUILDERS INC.
Site address
112 FRONT STREET
City
EXETER
State
NH
ZIP
03833
Mailing
113 LINDEN STREET, EXETER, NH 03833
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Last modified
Data loaded
NAICS code
236116
Employees
20
Ownership type
A

12 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $1702 · Current $1000 Reduced
29 CFR  1926.102(a)(1):  The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:  a. Site (Building 2) - Employees were using pneumatic nail guns to construct the building and were not utilizing eye protection.
Recent events (4)
  • — I (S) $1000
  • — I (S) $1000
  • — Z (S) $1702

1926.451 A06

Serious Gravity 10 6 instances 5 exposed
Issued
Abate by
Penalty
Initial $3972 · Current $2000 Reduced
29 CFR  1926.451(a)(6):  Scaffolds were not designed by a qualified person and constructed and loaded in accordance with that design:  Site (Building 2) - The employer constructed and utilized 10 outrigger scaffolds which were designed and constructed by a qualified person.
Recent events (4)
  • — I (S) $2000
  • — I (S) $2000
  • — Z (S) $3972

1926.451 B01

Serious Gravity 10 4 instances 5 exposed
Issued
Abate by
Penalty
Initial $0 · Current $0
29 CFR  1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports:  a.  Site (Building 2) - Employees were working on 10 outrigger scaffold platforms which were not fully planked and only 12 inches wide.
Recent events (4)
  • — I (S) $0
  • — I (S) $0
  • — Z (S) $0

1926.451 B04

Serious Gravity 10 2 instances 5 exposed
Issued
Abate by
Penalty
Initial $0 · Current $0
29 CFR  1926.451(b)(4): Each end of a platform, unless cleated or otherwise restrained by hooks or equivalent means, did not extend over the centerline of its support at least 6 inches (15 cm):  a.  Site  (Sides of Building 2) - Employees were working on 5 outrigger scaffolds with platforms that extended only 3 inches and were not secured to the supports / outriggers.
Recent events (4)
  • — I (S) $0
  • — I (S) $0
  • — Z (S) $0

1926.451 B05 II

Serious Gravity 5 8 instances 5 exposed
Issued
Abate by
Penalty
Initial $0 · Current $0
29 CFR  1926.451(b)(5)(ii):  Each platform greater than 10 feet in length extended over its support more than 18 inches (46 cm), unless it was designed and installed so that the cantilevered portion of the platform is able to support employees without tipping, or has guardrails which block employee access to the cantilevered end:  Site (Building 2) - Employees were working on 4 outrigger scaffolds which were greater than 10 feet in length and had platforms extending more than 18 inches over their supports where the ends were cantilevered and not secured.
Recent events (4)
  • — I (S) $0
  • — I (S) $0
  • — Z (S) $0

1926.452 I03

Serious Gravity 10 12 instances 5 exposed
Issued
Abate by
Penalty
Initial $0 · Current $0
29 CFR  1926.452(i)(3):  The fulcrum point of outrigger beams did not rest on secure bearings at least 6 inches (15.2 cm) in each horizontal dimension:  Site (Building 2) - The employer created 10 outrigger scaffolds, each of which was constructed of 2 outriggers.  Each outrigger was not resting on securing bearings at each fulcrum point for the outrigger beam.
Recent events (4)
  • — I (S) $0
  • — I (S) $0
  • — Z (S) $0

1926.452 I07

Serious Gravity 5 6 instances 5 exposed
Issued
Abate by
Penalty
Initial $0 · Current $0
29 CFR  1926.452(i)(7):  To prevent their displacement, platform units were not nailed, bolted, or otherwise secured to outriggers:  Site (Building 2) - Employees were working on 10 outrigger scaffold platforms which were not secured to the outriggers to prevent displacement.
Recent events (4)
  • — I (S) $0
  • — I (S) $0
  • — Z (S) $0

1926.452 I08

Serious Gravity 5 6 instances 5 exposed
Issued
Abate by
Penalty
Initial $0 · Current $0
29 CFR  1926.452(i)(8):  Scaffolds and scaffold components were not designed by a registered professional engineer and were not constructed and loaded in accordance with such design:  Site (Building 2) - Employees were working on 10 outrigger scaffolds which were constructed by employees rather than a registered professional engineer.
Recent events (4)
  • — I (S) $0
  • — I (S) $0
  • — Z (S) $0

1926.451 G01

Serious Gravity 10 4 instances 5 exposed
Issued
Abate by
Penalty
Initial $3972 · Current $2000 Reduced
29 CFR  1926.451(g)(1):  Each employee on a scaffold more than 10 feet (3.1 m) above a lower level was not protected from falling to that lower level:  a.  Site (Back of Building 2)- Employees working on 4 outrigger scaffolds were not protected from falls of approximately 22 feet to the ground.  b.  Site (Sides of Building 2) - Employees working on 6 outrigger scaffolds were not protected from falls of approximately 15 feet to the ground.
Recent events (4)
  • — I (S) $2000
  • — I (S) $2000
  • — Z (S) $3972

1926.501 B13

Serious Gravity 5 16 instances 9 exposed
Issued
Abate by
Penalty
Initial $0 · Current $0
29 CFR  1926.501(b)(13):   Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest system:  Site (Building 2) - Employees working throughout building 2, floors 2 and 3, were exposed to falls from the building window openings where there was inadequate fall protection.
Recent events (4)
  • — I (S) $0
  • — I (S) $0
  • — Z (S) $0

1926.1053 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0 · Current $0
29 CFR  1926.1053(b)(1):  When portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface:  Site (Building 2) - Employees were using a portable ladder to access the outrigger scaffolding which did not extend at least 3 feet above the upper landing surface.
Recent events (4)
  • — I (S) $0
  • — I (S) $0
  • — Z (S) $0

1926.1052 C01

Serious Gravity 1 4 instances 9 exposed
Issued
Abate by
Penalty
Initial $1702 · Current $1000 Reduced
29 CFR  1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, shall be equipped with at least one handrail:  Site (Building 2) - Employees working within the 4 units were not adequately protected from falls in stairways which did not have handrails.
Recent events (4)
  • — I (S) $1000
  • — I (S) $1000
  • — Z (S) $1702

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348861238.