OSHA Inspection: KHOBATAU INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of KHOBATAU INC. in 2559 EAST HAGERT STREET, PHILADELPHIA, PA 19125 (NAICS 238170). OSHA activity number 348867979.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Khobatau INC. for free Get an email when a new federal OSHA severe-injury report for Khobatau INC. is published. One employer, no account, unsubscribe in one click.
Establishment
KHOBATAU INC.
Site address
2559 EAST HAGERT STREET
City
PHILADELPHIA
State
PA
ZIP
19125
Mailing
86 CAMERON ROAD, HUNTINGDON VALLEY, PA 19006
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Last modified
Data loaded
NAICS code
238170
Employees
1
Ownership type
Private (A)

2 citations on file for this inspection.

1926.451 G04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jun 29, 2026
Penalty
Initial $3,972 · Current $3,972
29 CFR  1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews:  a) Jobsite located at or near 2559 East Hagert Street, Philadelphia, PA 19125 - On or about April 8, 2026, the employer did not ensure that all open sides and ends of the scaffold were protected by use of guardrail systems, thereby exposing an employee conducting siding installation on a residential building to falls of approximately 20 feet.
Recent events (1)
  • · Z (S) $3972

1926.452 J02

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 29, 2026
Penalty
Initial $2,270 · Current $2,270
29 CFR  1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary:  a) Jobsite located at or near 2559 East Hagert Street, Philadelphia, PA 19125 - On or about April 8, 2026, the employer did not ensure that the poles to an Alum-A-Pole pump jack scaffold were secured to the structure by rigid triangular bracing or equivalent at the bottom of the poles as needed before use, thereby exposing an employee to fall hazards. An employee was conducting siding installation from the platform of an Alum-A-Pole pump jack scaffold approximately 20 feet above ground level.