LOS ANGELES, CA —
OSHA Inspection: U.S. POSTAL SERVICE
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of U.S. POSTAL SERVICE in 7001 S. CENTRAL AVE, LOS ANGELES, CA 90052 (NAICS 491110). OSHA activity number 348883885.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- U.S. POSTAL SERVICE
- Site address
- 7001 S. CENTRAL AVE
- City
- LOS ANGELES
- State
- CA
- ZIP
- 90052
- Mailing
- 7001 S. CENTRAL AVE ROOM 51, LOS ANGELES, CA 90052
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Last modified
- Data loaded
Establishment context
- NAICS code
- 491110
- Employees
- 1862
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.151 C
- Issued
- Jun 9, 2026
- Abate by
- Jul 28, 2026
- Penalty
- Initial $16,550 · Current $16,550
General-duty citation text
29 CFR 1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use. (a) Entire Facility : On or about April 15th, 2026, the employer failed to provide an emergency eyewash station within the immediate vicinity of employees working with and around a Toyota Electric Forklift Model 7FBEU15 , Toyota Rider Pallet Jack Model 8HBE40, Toyota Electric Tow Truck 8TB50, Big Joe S22-62 Electric Straddle Stacker and Enersys NEXSYS Model NIP3-JN-4Y 480DC Forklift Battery Charger. (b) Expansion Building 163 Hazard Materials Room: On or about April 15th, 2026, the plumbed eye wash station did not provide adequate water pressure when activated.
Recent events (1)
- — Z (S) $16550
1910.164 C01
- Issued
- Jun 9, 2026
- Abate by
- Jul 28, 2026
- Penalty
- Initial $14,188 · Current $14,188
General-duty citation text
29 CFR 1910.164(c)(1): The employer did not maintain all systems in an operable condition except during repairs or maintenance. Entire Facility: On or about April 15, 2026, the Edwards EST3 fire alarm system was displaying several error codes.
Recent events (1)
- — Z (S) $14188
1910.178 N04
- Issued
- Jun 9, 2026
- Abate by
- Jul 7, 2026
- Penalty
- Initial $14,188 · Current $14,188
General-duty citation text
29 CFR 1910.178(n)(4): The industrial truck driver shall be required to slow down and sound the horn at cross aisles and other locations where vision is obstructed. If the load being carried obstructs forward view, the driver shall be required to travel with the load trailing. Entire Facility: On or about April 15th, 2026, employees operating a Toyota Electric Forklift Model 7FBEU15 , Toyota Rider Pallet Jack Model 8HBE40 and Toyota Electric Tow Truck 8TB50 , while driving through intersections and aisleways, did not sound the horn or slow down to come to a complete stop.
Recent events (1)
- — Z (S) $14188
1910.178 Q01
- Issued
- Jun 9, 2026
- Penalty
- Initial $12,059 · Current $12,059
General-duty citation text
29 CFR 1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and repairs were not made by authorized personnel.. Area BB10: On or about April 15th, 2026, the employer did not ensure removal of the Toyota Rider Pallet Jack Model 8HBE40, that was not in safe operating condition due to exposed battery connector wiring.
Recent events (1)
- — Z (S) $12059
1910.212 A01
- Issued
- Jun 9, 2026
- Abate by
- Jul 7, 2026
- Penalty
- Initial $14,188 · Current $14,188
General-duty citation text
29 CFR 1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks. (a) Maintenance Shop: On or about April 15th, 2026, employees performed maintenance activities while utilizing a OTC 25 Ton Hydraulic Press ( Model 1833) without proper guarding. (b) High Speed Tray Sorter (HSTS) : On or about April 16th, 2026, employees performed mail processing activities while utilizing several USPS Automatic Tray Unsleever (ATU) without proper guarding.
Recent events (1)
- — Z (S) $14188
1910.244 A01 II
- Issued
- Jun 9, 2026
- Abate by
- Jul 7, 2026
- Penalty
- Initial $11,348 · Current $11,348
General-duty citation text
29 CFR 1910.244(a)(1)(ii): The rated load shall be legibly and permanently marked in a prominent location on the jack by casting, stamping, or other suitable means. Dock Area (Mckinley Door 2) : On or about April 15th 2026 , several JET PT-2742JA 5500 Lb 27" x 42" Pallet Truck (161008) that did not have the rated loads permanently marked on the equipment were in the pallet jack station near the truck dock area.
Recent events (1)
- — Z (S) $11348
1910.303 G01 II
- Issued
- Jun 9, 2026
- Penalty
- Initial $7,235 · Current $7,235
General-duty citation text
29 CFR 1910.303(g)(1)(ii): The required working space about electrical equipment rated 600 volts, nominal, or less to ground, was in a passageway or general open space and was not suitably guarded when normally enclosed live parts were exposed for inspection or servicing: On or about April 15th, 2026, several miscellaneous items were placed within 36 inches of the circuit breaker panel. (a) Break Area 7 (BB8) (b) Forklift Charging Area (BB10)
Recent events (1)
- — Z (S) $7235
1910.305 G01 IV A
- Issued
- Jun 9, 2026
- Penalty
- Initial $14,188 · Current $14,188
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure: Custodial Storage Room 100 : On or about April 15th, 2026, a yellow flexible cord was used as a source of permanent power and was used to power battery chargers.
Recent events (1)
- — Z (S) $14188
More inspections at U.S. Postal Service
View U.S. Postal Service's full OSHA safety record →
More inspections in this industry (NAICS 491110)
More inspections in CA
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348883885.