Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: U.S. POSTAL SERVICE

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of U.S. POSTAL SERVICE in 7001 S. CENTRAL AVE, LOS ANGELES, CA 90052 (NAICS 491110). OSHA activity number 348883885.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch U.S. Postal Service — free Get an email when a new federal OSHA severe-injury report for U.S. Postal Service is published. One employer, no account, unsubscribe in one click.
Establishment
U.S. POSTAL SERVICE
Site address
7001 S. CENTRAL AVE
City
LOS ANGELES
State
CA
ZIP
90052
Mailing
7001 S. CENTRAL AVE ROOM 51, LOS ANGELES, CA 90052
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Last modified
Data loaded
NAICS code
491110
Employees
1862
Ownership type
A

8 citations on file for this inspection.

1910.151 C

Serious Gravity 10 2 instances 1862 exposed
Issued
Jun 9, 2026
Abate by
Jul 28, 2026
Penalty
Initial $16,550 · Current $16,550
29 CFR  1910.151(c): Where the eyes or body of any person may be exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body shall be provided within the work area for immediate emergency use.  (a) Entire Facility : On or about April 15th, 2026, the employer failed to provide an emergency eyewash station within the immediate vicinity of employees working with and around a Toyota Electric Forklift Model 7FBEU15 , Toyota Rider Pallet Jack Model 8HBE40, Toyota Electric Tow Truck 8TB50, Big Joe S22-62 Electric Straddle Stacker and Enersys NEXSYS Model NIP3-JN-4Y 480DC Forklift Battery Charger.  (b) Expansion Building 163 Hazard Materials Room: On or about April 15th, 2026, the plumbed eye wash station did not provide adequate water pressure when activated.
Recent events (1)
  • — Z (S) $16550

1910.164 C01

Serious Gravity 5 1 instance 1862 exposed
Issued
Jun 9, 2026
Abate by
Jul 28, 2026
Penalty
Initial $14,188 · Current $14,188
29 CFR 1910.164(c)(1): The employer did not maintain all systems in an operable condition except during repairs or maintenance.  Entire Facility: On or about April 15, 2026, the Edwards EST3 fire alarm system was displaying several error codes.
Recent events (1)
  • — Z (S) $14188

1910.178 N04

Serious Gravity 5 1 instance 1862 exposed
Issued
Jun 9, 2026
Abate by
Jul 7, 2026
Penalty
Initial $14,188 · Current $14,188
29 CFR  1910.178(n)(4): The industrial truck driver shall be required to slow down and sound the horn at cross aisles and other locations where vision is obstructed. If the load being carried obstructs forward view, the driver shall be required to travel with the load trailing.  Entire Facility: On or about April 15th, 2026, employees operating a Toyota Electric Forklift Model 7FBEU15 , Toyota Rider Pallet Jack Model 8HBE40 and Toyota Electric Tow Truck 8TB50 , while driving through intersections and aisleways, did not sound the horn or slow down to come to a complete stop.
Recent events (1)
  • — Z (S) $14188

1910.178 Q01

Serious Gravity 5 1 instance 1 exposed
Issued
Jun 9, 2026
Penalty
Initial $12,059 · Current $12,059
29 CFR  1910.178(q)(1): Any power-operated industrial truck not in safe operating condition was not taken out of service, and repairs were not made by authorized personnel..   Area BB10: On or about April 15th, 2026, the employer did not ensure removal of the Toyota Rider Pallet Jack Model 8HBE40, that was not in safe operating condition due to exposed battery connector wiring.
Recent events (1)
  • — Z (S) $12059

1910.212 A01

Serious Gravity 5 2 instances 687 exposed
Issued
Jun 9, 2026
Abate by
Jul 7, 2026
Penalty
Initial $14,188 · Current $14,188
29 CFR  1910.212(a)(1): Types of guarding. One or more methods of machine guarding shall be provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.   (a) Maintenance Shop: On or about April 15th, 2026, employees performed maintenance activities while utilizing a OTC 25 Ton Hydraulic Press ( Model 1833) without proper guarding.  (b)  High Speed Tray Sorter (HSTS) :  On or about April 16th, 2026, employees performed mail processing activities while utilizing several USPS Automatic Tray Unsleever (ATU) without proper guarding.
Recent events (1)
  • — Z (S) $14188

1910.244 A01 II

Serious Gravity 5 1 instance 125 exposed
Issued
Jun 9, 2026
Abate by
Jul 7, 2026
Penalty
Initial $11,348 · Current $11,348
29 CFR  1910.244(a)(1)(ii): The rated load shall be legibly and permanently marked in a prominent location on the jack by casting, stamping, or other suitable means.  Dock Area (Mckinley Door 2) :  On or about April 15th 2026 , several JET PT-2742JA 5500 Lb 27" x 42" Pallet Truck (161008) that did not have the rated loads permanently marked on the equipment were in the pallet jack station near the truck dock area.
Recent events (1)
  • — Z (S) $11348

1910.303 G01 II

Serious Gravity 1 2 instances 1862 exposed
Issued
Jun 9, 2026
Penalty
Initial $7,235 · Current $7,235
29 CFR 1910.303(g)(1)(ii): The required working space about electrical equipment rated 600 volts, nominal, or less to ground, was in a passageway or general open space and was not suitably guarded when normally enclosed live parts were exposed for inspection or servicing:  On or about April 15th, 2026, several miscellaneous items were placed within 36 inches of the circuit breaker panel.   (a) Break Area 7 (BB8) (b) Forklift Charging Area (BB10)
Recent events (1)
  • — Z (S) $7235

1910.305 G01 IV A

Serious Gravity 5 1 instance 115 exposed
Issued
Jun 9, 2026
Penalty
Initial $14,188 · Current $14,188
29 CFR  1910.305(g)(1)(iv)(A): Flexible cords and cables were used as a substitute for the fixed wiring of a structure:  Custodial Storage Room 100 : On or about April 15th, 2026, a yellow flexible cord was used as a source of permanent power and was used to power battery chargers.
Recent events (1)
  • — Z (S) $14188

View U.S. Postal Service's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 348883885.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.